Incoming-Outgoing Devices Coating Acceptance without Bakeout Pumping Speed Acceptance with Bakeout Leak Check Safety im Labor
  Incoming-Outgoing Devices  Not logged in ELOG logo
Message ID: 26     Entry time: Fri Nov 22 11:10:33 2019
Author: Phe 
Category: test with bakeout 
Subject: Dipole Chambers for SIS100 (2box) 
Expected: 25.11.19 
Current Status: Delayed 
New Expected Date: Unknown 
Date Received: 17.01.20 
Status: DONE 
Visual Inspection: Accepted 
Test Started: 12.02.2020 
Setup:  
Test Ended: End februar 
Result: Accepted 
Outgoing Date:  
Taken by:  
All chambers are inserted with success into the magnet. Leak check for: 07-6-013-3; 07-6-009-6; 07-6-011-9