Incoming-Outgoing Devices
Coating
Acceptance without Bakeout
Pumping Speed
Acceptance with Bakeout
Leak Check
Safety im Labor
|
| Incoming-Outgoing Devices |
Not logged in |
 |
|
|
Message ID: 61
Entry time: Wed Mar 4 10:06:09 2020
|
| Author: |
Phe |
| Category: |
leak check |
| Subject: |
Transistion tube for SIS100 string test_Second test |
| Expected: |
Beginning 2020 |
| Current Status: |
Delayed |
| New Expected Date: |
February |
| Date Received: |
End of February |
| Status: |
DONE |
| Visual Inspection: |
Accepted |
| Test Started: |
03.03.2020 |
| Setup: |
Customised |
| Test Ended: |
03.03.2020 |
| Result: |
Accepted |
| Outgoing Date: |
5.03.2020 |
| Taken by: |
Ivan and Stefan (for integration @BNG) |
|
|
|
|
|