Entry  Wed May 11 03:17:14 2022, Patrick, Volker, Guy , Runs, Start laser scanning 
    Reply  Wed May 11 08:01:44 2022, Zoran, Runs, Start laser scanning 
Message ID: 37     Entry time: Wed May 11 03:17:14 2022     Reply to this: 42
Author: Patrick, Volker, Guy  
Category: Runs 
Subject: Start laser scanning 
Runs of the night shift. The wavelength range is 601.95 - 601.735 nm.
We started the wavemeter python script on atppc023 located in Desktop/wavemeter_Bi.
We changed the wavelength range in go4 to the actual scan range.

Questions:
There are many other masses/isotopes/etc. visible in the Shottky spectrum. Is this wanted?
Are the vacuum gauges turned off?
Laser timing correct? +- 3 bins?

TimeSIS-intensitycooler-HVLMD-DAQ2 file nr LMD-DAQ1 file nr scan range(nm)step width(nm)dwell time(s)comments
03:30 ?e7 223218 373 8073 601.95 - 601.735 0.005 5s 2 loops
03:38 9.0e7 223218 374-377 8074 601.95 - 601.735 0.005 5s 8 loops from now on
04:15 8.4e7 223218 378 - 381 8075 601.95 - 601.735 0.005 5s
04:49 7.4e7 223217 382 - 385 8076 601.95 - 601.735 0.005 5s
05:23 6.4e7 223216 386 - 388 8078 601.95 - 601.735 0.005 5s 8077 was skipped due to some "server socket locked"-error
05:59 8.9e7 223218 389 - 391 8079 601.95 - 601.735 0.005 5s