HOME
ESR
EXPERIMENTS
LABS etc
|
E121
E127
E132
E125
E143
laser_cooling_2021
E142
Ê128
E146
E0052
E0018
|
Dielectronic recombination-assisted laser spectroscopy |
Not logged in |
|
|
Message ID: 91
Entry time: Mon May 30 19:00:19 2022
|
Author: |
Carsten |
Category: |
General |
Subject: |
Scraper Settings and Parameters for the last measrements with thick target |
|
|
old Bunch frequency: 1.98777 MHz
Positions PL devices:
GE01DD2AG | -23
|
GE01DD2IG | 3
|
GE02DD2_G | -35
|
GE02DS3HG | 0
|
The voltages of the particle detectors were set to:
SA_SZ: 1500V
NA_SZ: 750V
But for the primatry beam measurements the detectors were still switched off
Set values for cooler:
SC3: 223513.377 + DeltaU = 160V
SC6: 223452.14 + DeltaU = 130V
SC9: 223452.14 + DeltaU = 130V
Electron current:
SC3: 300mA
SC6: 100mA (300mA in the second file)
SC9: 100ma (300mA in the second file)
Cooling in SC4: 550x
Cooling in SC7: 50x
Explanation of subchains:
SC4: Cooling at injection orbit
SC5: Ramp to central orbit
SC7: Cooling at central orbit
SC8: Scrapers /particle detectors in, XUV detector in, (~10s), bunching on
SC9: measurement
SC10: not used
SC11: Scrapers/particle detectors/XUV ectros out (~10s), bunching off |
|
|