Message ID: 54     Entry time: Tue May 13 21:37:09 2025
Author: Carsten 
Category: Runs 
Subject: DR run with bunched beam / 500 mA /208Bi80+ 
Just changed settings towards a new scanning range and bunched beam.
Stopped and started NTCAP, now: IQ_2025-05-13_21-01-44
new ADC file
NEW ENERGY RANGE AND TIMING
Scan from 21 eV to 11 eV with 1001 steps and Delta E = 0.01 eV
8 repetitions
SubTriggerTiming:
5800
10200
10400
10600
200
200
200

500 mA / bunched beam; other settings as before

run0035.lmd opened

Please note that the peak now looks differently, in particular in looks broader (dE = 0.01ev instead of dE =0.02 eV))and is at a different position