Time | File | Ohmlabs | PTB 32 | PTB 33 | ESR intensity SC8 / 1e6 | Typical SIS injections / 1e9 | NTCAP file | comments |
2025-05-18 08:21 | 140 | 205821 | 205827 | 205828 | 2.4 | 1.6 | SC_2025-05-18_07-57-22 | morning shift starts |
2025-05-18 08:57 | 141 | 205821 | 205828 | 205829 | 3.3 | 1.4 | SC_2025-05-18_07-57-22 | |
2025-05-18 09:32 | 142 | 205821 | 205828 | 205829 | 2.5 | 1.7 | SC_2025-05-18_07-57-22 | |
2025-05-18 10:08 | 143 | 205821 | 205828 | 205829 | 1.3 | 2.0 | SC_2025-05-18_07-57-22 | strong drop in ESR intensity after injection |
2025-05-18 10:43 | 144 | 205822 | 205828 | 205829 | 3.4 | 1.8 | SC_2025-05-18_07-57-22 | |
2025-05-18 11:19 | 145 | 205820 | 205828 | 205829 | 1.1 | 1.5 | SC_2025-05-18_07-57-22 | strong drop in ESR intensity after injection (see screenshot), laser scan started a few seconds too late |
2025-05-18 11:55 | 146 | 205822 | 205828 | 205829 | 0.9 | 1.5 | SC_2025-05-18_07-57-22 | strong drop in ESR intensity after injection, worse than before, decreasing SIS intensity |
2025-05-18 12:00 | | | | | | | | called HKR, reported ESR drop, they checked but see no clear reason, ESR crew will be called for help, see 2nd screenshot |
2025-05-18 12:15 | | | | | | | | Sergey called, we should stop requesting after ESR cycle, then send "ganzen Kontext" (ParamModi) and then request beam again |
2025-05-18 12:29 | 147 | 205822 | 205828 | 205829 | 0.4 | 1.0 | SC_2025-05-18_07-57-22 | again drop in ESR intensity after injection, SIS18 intensity was increased during accumulation |
2025-05-18 12:40 | | | | | | | | we sent "ganzen Kontext" (ParamModi) and then request beam again |
2025-05-18 13:04 | 148 | 205821 | 205828 | 205829 | 1.3 | 2.5 | SC_2025-05-18_07-57-22 | looks better now |
2025-05-18 13:15 | | | | | | | | stopped ESR cycle, stopped NTCAP, Sergey will check ESR settings, maybe improvement is possible |
2025-05-18 13:45 | | | | | | | | ESR cycle running but was interrupted, DRALS was still running, we waited until DRALS end, then started ESR cycle again. We changed time between SIS18 injections from 40 s to 20 s |
2025-05-18 14:14 | 149 | 205826 | 205833 | 205834 | 5.7 | 3.5 | SC_2025-05-18_13-52-38 | the losses after injection (in SC5) are gone!! (see 3rd screenshot) HV values slightly drifted, ~5 V |
2025-05-18 14:49 | 150 | 205819 | 205826 | 205827 | 2.6 | 2.5 | SC_2025-05-18_13-52-38 | slight SC5 losses again, and HV values again slightly drifted, ~3 V |
2025-05-18 15:24 | 151 | 205821 | 205828 | 205829 | 1.8 | 2.3 | SC_2025-05-18_13-52-38 | slight SC5 losses again, HV values back to normal |
2025-05-18 16:00 | 152 | 205824 | 205831 | 205832 | 0.7 | 2.6 | SC_2025-05-18_13-52-38 | low ESR intensity, HV slightly different |
|