Message ID: 91     Entry time: Sun May 18 08:06:55 2025
Author: Danyal, Christopher, Jonas 
Category: Runs 
Subject: morning shift 
Took over from night shift and keep scanning
Time File Ohmlabs PTB 32 PTB 33 ESR intensity SC8 / 1e6 Typical SIS injections / 1e9 NTCAP file comments
2025-05-18 08:21 140 205821 205827 205828 2.4 1.6 SC_2025-05-18_07-57-22 morning shift starts
2025-05-18 08:57 141 205821 205828 205829 3.3 1.4 SC_2025-05-18_07-57-22
2025-05-18 09:32 142 205821 205828 205829 2.5 1.7 SC_2025-05-18_07-57-22
2025-05-18 10:08 143 205821 205828 205829 1.3 2.0 SC_2025-05-18_07-57-22 strong drop in ESR intensity after injection
2025-05-18 10:43 144 205822 205828 205829 3.4 1.8 SC_2025-05-18_07-57-22
2025-05-18 11:19 145 205820 205828 205829 1.1 1.5 SC_2025-05-18_07-57-22 strong drop in ESR intensity after injection (see screenshot), laser scan started a few seconds too late
2025-05-18 11:55 146 205822 205828 205829 0.9 1.5 SC_2025-05-18_07-57-22 strong drop in ESR intensity after injection, worse than before, decreasing SIS intensity
2025-05-18 12:00 called HKR, reported ESR drop, they checked but see no clear reason, ESR crew will be called for help, see 2nd screenshot
2025-05-18 12:15 Sergey called, we should stop requesting after ESR cycle, then send "ganzen Kontext" (ParamModi) and then request beam again
2025-05-18 12:29 147 205822 205828 205829 0.4 1.0 SC_2025-05-18_07-57-22 again drop in ESR intensity after injection, SIS18 intensity was increased during accumulation
2025-05-18 12:40 we sent "ganzen Kontext" (ParamModi) and then request beam again
2025-05-18 13:04 148 205821 205828 205829 1.3 2.5 SC_2025-05-18_07-57-22 looks better now
2025-05-18 13:15 stopped ESR cycle, stopped NTCAP, Sergey will check ESR settings, maybe improvement is possible
2025-05-18 13:45 ESR cycle running but was interrupted, DRALS was still running, we waited until DRALS end, then started ESR cycle again. We changed time between SIS18 injections from 40 s to 20 s
2025-05-18 14:14 149 205826 205833 205834 5.7 3.5 SC_2025-05-18_13-52-38 the losses after injection (in SC5) are gone!! (see 3rd screenshot) HV values slightly drifted, ~5 V
2025-05-18 14:49 150 205819 205826 205827 2.6 2.5 SC_2025-05-18_13-52-38 slight SC5 losses again, and HV values again slightly drifted, ~3 V
2025-05-18 15:24 151 205821 205828 205829 1.8 2.3 SC_2025-05-18_13-52-38 slight SC5 losses again, HV values back to normal
2025-05-18 16:00 152 205824 205831 205832 0.7 2.6 SC_2025-05-18_13-52-38 low ESR intensity, HV slightly different
Attachment 1: 2025-05-18_11-10-39-917_tcl1146.png  247 kB  Uploaded Sun May 18 12:23:48 2025  | Hide | Hide all | Show all
2025-05-18_11-10-39-917_tcl1146.png
Attachment 2: Bildschirmfoto_2025-05-18_12-22-37.png  65 kB  Uploaded Sun May 18 13:24:39 2025  | Hide | Hide all | Show all
Bildschirmfoto_2025-05-18_12-22-37.png
Attachment 3: 2025-05-18_14-19-08-249_tcl1146.png  254 kB  Uploaded Sun May 18 15:20:53 2025  | Show | Hide all | Show all
ELOG V3.1.5-fc6679b