Message ID: 92     Entry time: Sun May 18 16:08:58 2025
Author: Wilfried, Carsten, Rodolfo, Hendrik 
Category: Runs 
Subject: Afternoon shift, continued measurements 
Took over from morning shift and keep scanning
Time File Ohmlabs PTB 32 PTB 33 ESR intensity SC8 / 1e6 Typical SIS injections / 1e9 NTCAP file comments
2025-05-18 16:35 153 205821 205827 205817 0.8 2.3 SC_2025-05-18_13-52-38 Inconsistent SIS Injections, Voltages all drifted slightly, checked the beam positions by moving the scraper on the remaining ions after scan, Scraper GECEDS2HU was used and the horizontal alignment was confirmed to still be good, Carsten re-sent some SIS commands but changed nothing
2025-05-18 17:38 154 205822 205828 205829 0.7 2.0 SC_2025-05-18_13-52-38 Unlucky SIS injections, Voltages do not drift much anymore, beam after scan was used to scrape again, checked vertical alignment with GECEDS1VU, ion beam located at -0.5, laser beam still clearly visible, around 4mm too high compared to ion beam, GECEDS1HU confirms horizontal alignment is also good like in Scraper 2
2025-05-18 18:43 155 205824 205830 205831 0.9 2.5 SC_2025-05-18_13-52-38 GECEDS1HU destroyed ion beam at -13.0
2025-05-18 19:32 156 205822 205829 205830 0.8 3.0 SC_2025-05-18_13-52-38 First few SIS injections were very bad, after that very good, 0.5 on GECEDS2VU and the ion beam vanishes, fits good with laser beam, delay of the laser reduced by 7ns
2025-05-18 20:21 157 205822 205828 205830 0.8 2.4 SC_2025-05-18_13-52-38
2025-05-18 20:57 158 205822 205828 205830 0.7 2.5 SC_2025-05-18_13-52-38
2025-05-18 21:38 159 205820 205826 205828 1.3 2.8 SC_2025-05-18_13-52-38
2025-05-18 22:13 160 205820 205826 205827 1.0 2.8 SC_2025-05-18_13-52-38
2025-05-18 22:46 161 205820 205826 205827 1.7 2.9 SC_2025-05-18_13-52-38
2025-05-18 23:22 162 205822 205829 205830 3.5 2.7 SC_2025-05-18_13-52-38 While scanning, at step 16 something weird happened and the accumulated counts decreased only in that step
2025-05-18 00:00 163 205822 205828 205829 5.0 2.8 SC_2025-05-18_13-52-38 22 injections and 75 breeding cycles


Timing: We shifted the laser approximately 8 ns to an earlier time to compensate for the 2-3 m distance between the target and the detection region (please note that earlier times are located to the right since the x-axis is the time after the event until the common stop). The positions of the laser pulse on the photodiodes are therefore shifted to the right.
Attachment 1: Bildschirmfoto_2025-05-18_21-10-46.png  34 kB  Uploaded Sun May 18 22:45:46 2025  | Show | Show all