Sat May 17 21:27:17 2025, Wilfried, Rodolfo, Laser, Scraping the laser beam
|
The beam stabilization in not working properly. So we have turned it off. We also scraped the laser beam at the E-Cooler and bring the laser beam to the
right position.
|
Sat May 17 21:40:40 2025, Wilfried, Rodolfo, Hendrik, Ragandeep, Yuri, Laser, Eveningshift data runs
|
[TABLE border="1"]
Time |File | Ohmlabs | PTB 32 | PTB 33 | ESR intensity SC8 / 1e6 | Typical SIS injections / 1e9 | NTCAP file | comments |-
|
Sun May 18 00:25:08 2025, Finn, Konstantin, Dimitrios, Laser, Nightshift data runs
|
Took over from afternoon shift and keep scanning
[TABLE border="1"]
Time |File | Ohmlabs | PTB 32 | PTB 33 | ESR intensity SC8 / 1e6 | Typical SIS injections / 1e9 | NTCAP file | comments |-
|
Sun May 18 01:47:56 2025, Konstantin, DAQ, Particle detector
|
The attachment shows the signal of the particle detector for bunched beam (red, files 104-112) coasting beam (black, files 113-117) as a function of the
time for one cycle of the DRALS pattern. One can identify modulations of the signal during the cooling step in both traces. However, there are some clear
differences:
|
Sun May 18 02:24:46 2025, Wilfried, Rodolfo, Carsten, Detectors, Antrieb Cu-Mirror defekt
|
On Saturday afternoon we moved the Cu mirror to the inner position, however an issue appeared when we tried to move the mirror to the "park" position. The
stepping motor did not react properly, it clamped. After restarting the software we could actually move the mirror out, but the stepping motor as well
as driving system made a lot of noise until the parking position was reached. This issue has to be investigated specialists after the beamtime. |
Sun May 18 04:33:46 2025, Dimitrios, Finn, Konstantin, Laser, Laser position
|
We changed the position of the laser back to the position which was set up in [COLOR=blue][B][URL=https://elog.gsi.de/esr/E0038/85]E 85[/URL][/B][/COLOR]
by changing the motor position of motor 4 in the kangoo software at ATPPC031 from -0.1 to -0.3. |
Sun May 18 08:06:55 2025, Danyal, Christopher, Jonas, Runs, morning shift  
|
Took over from night shift and keep scanning
[TABLE border="1"]
Time |File | Ohmlabs | PTB 32 | PTB 33 | ESR intensity SC8 / 1e6 | Typical SIS injections / 1e9 | NTCAP file | comments |-
|
Sun May 18 16:08:58 2025, Wilfried, Carsten, Rodolfo, Hendrik, Runs, Afternoon shift, continued measurements
|
Took over from morning shift and keep scanning
[TABLE border="1"]
Time |File | Ohmlabs | PTB 32 | PTB 33 | ESR intensity SC8 / 1e6 | Typical SIS injections / 1e9 | NTCAP file | comments |-
|
Sun May 18 21:30:20 2025, Wilfried, Rodolfo, Markus, Zoran, Accelerator, T-Scrapers, Update
|
Here are the right instructions to drive the T-Scrapers inside the ESR Electron Cooler
[LIST]
|
Mon May 19 00:28:40 2025, Simon, Finn, Runs, Night shift measurement 
|
Took over from afternoon shift and keep scanning
[TABLE border="1"]
Time |File | Ohmlabs | PTB 32 | PTB 33 | ESR intensity SC8 / 1e6 | Typical SIS injections / 1e9 | NTCAP file | comments |-
|
Tue May 27 10:56:44 2025, Konstantin, DAQ, Common stop
|
The common stop was wired through a 1:2, and subsequently through a 1:99 rate divider channel. However, since the pulse width was too long, the 1:2 channel
was translated into a 1:4 reduction. This must be considered, when the data is processed via go4. The reduction factor in the SetParameters.C file must
be set to 198 accordingly. |