  Nuclear hyperfine mixing in 229Th89+ 2024  Not logged in ELOG logo
This is a draft message, edit and submit it to make it permanent  
Message ID: 21     Entry time: Thu Jun 6 07:54:15 2024
Author: Danyal 
Category: General 
Subject: pressure gauges and ion pumps  
yesterday (05.06.2024), firstly, the two ion pumps (underneath the fluorescence chamber) were switched off by the vacuum group (Björn Mai, Tel: 3438). Secondly, the two pressure gauges (located near the target) were switched off.  The pressure gauge at the fluo chamber is called E02VM3x and the pressure was 5.5e-11 mbar.  The other gauge is called IG2 and located further south, it measured 3.7e-11 mbar.  That was when ion pumps were still switched on.  Since ~10:45 (05.06.2024), the two ion pumps and the two ion gauges are switched off. There was no measurable change in the pressure after switching off the ion pumps.