    Entry time: Tue Apr  1 22:05:24 2025
 |  
| Author: | 
Ruijiu   | 
 | Category: | 
Analysis  | 
 | Subject: | 
analysis result  | 
 
  |  
 
 | 
This is a preliminary result during 4:00-19:00 April 1st 2025. 
I correct the frequency drift of 194Pb82+ ions injection by injection.
I have analyzed all injection data during 4:00-19:00 and calculated the frequency of 194Pb82+ for each injection. This is the frequency of 194Pb82+ as 
a function of time. You can clearly see that the frequency of 194Pb82+ was drifted from 408.603 to 408.600 MHz. The variation of frequency is about 
3kHz.  | 
 | 
 
 | 
 | 
 
 | 
 | 
 
 | 
 | 
 
 |