HOME ESR EXPERIMENTS LABS etc
E121 E127 E132 E125 E143 laser_cooling_2021 E142 Ê128 E146 E0052 E0018 E0028 E0038 E0075 E0203_E0018
  masses & isomeres 2025, Page 1 of 17  Not logged in ELOG logo
ID Date Authordown Category Subject
  139   Fri Apr 4 02:51:30 2025 zhang, zhouGeneralscreenshot
  140   Fri Apr 4 03:44:59 2025 zhang, zhouGeneralscreenshot
  141   Fri Apr 4 04:45:39 2025 zhang, zhouGeneralscreenshot
  142   Fri Apr 4 05:45:37 2025 zhang, zhouGeneralscreenshot
  143   Fri Apr 4 06:45:12 2025 zhang, zhouGeneralscreenshot
  251   Sun Apr 6 22:57:47 2025 siddharth, dima, Taka, MoriguchiGeneralLassie screenshots
  163   Fri Apr 4 17:30:25 2025 siddharthAnalysisSigma vs Mean Freq. Plot for 188Hf72+ setting
  269   Mon Apr 7 11:26:52 2025 siddharthAnalysisSigma vs Mean Freq. Plot for 186Hf setting
1st plot is of Sigma vs Freq for 186Hf72+ setting. The green vertical line is at 411.843MHz.
2nd plot is of Sigma vs Freq for 186Hf72+ setting from april 4th 20:00 to April 5th 09:00 with time cut 0.14, shift tracking applied and pwr-limit 100. About 5200 Injections.
  270   Mon Apr 7 11:35:23 2025 siddharthAnalysisSigma vs Mean Freq. Plot for 186Hf setting
1st plot is of Sigma vs Freq for 186Hf72+ setting. The green vertical line is at 411.843MHz.
2nd plot is of Sigma vs Freq for 186Hf72+ setting from April 4th 20:00 to April 5th 09:00 with time cut 0.14, shift tracking applied and pwr limit 100, about 5200 injections.( the green vertical line is at 411.843 and not at 411.7) 
  312   Tue Apr 8 12:08:56 2025 siddharthAnalysisSigma vs Mean Freq. Plot for 188Hf72+ setting 2
This is sigma vs Freq plot for 188Hf72+ made out of 1hr of injections post Saturday, April 5th. 
The 2nd photo Compares the resolution of 188Hf setting by looking at peaks of 205Au and 205Pb which are very close in frequency range. The resolution in the second 188Hf72+ setting(on Right) seems much better as two peaks can be seen clearly. 
  8   Mon Mar 31 16:05:48 2025 ruijiu, shahab, yuyue, zac, carlo, erstherAnalysischeck the trigger signal in the scaler data of NTCAP
1. convert copy a tdms file into the folder:
(pyroot) gpuuser@appc256:/data.local/G22-00018_00203/data/ntcap/sc/SC_2025-03-28_18-48-51$ cp /mnt/ntcap-data2/G22-00018_00203/data/ntcap/sc/SC_2025-03-28_18-
48-51/0000216.sc.tdms ./
2. convert the tdms file into root file.
(pyroot) gpuuser@appc256:/data.local/G22-00018_00203/data/ntcap/sc/SC_2025-03-28_18-48-51$ /data.local/G22-
00018_00203/scripts/OnlineDataAnalysisSystem/iqt7/convert_iqt_sc -i 0000216.sc.tdms  -o ./
3. plot the result.
picture 1,2: trigger vs time
picture 3: solfware trigger vs time
  16   Mon Mar 31 23:34:58 2025 ruijiu, shahab, yuri, wolfram, sergeyAnalysisidentificaton of 194Pb82+
datafile = "/data.local/G22-00018_00203/results/analyzers/RSA01/RSA01-2025.03.31.22.18.16.965.tiq_spectrum.npz"
filep = "/data.local/G22-00018_00203/scripts/OnlineDataAnalysisSystem/rionid_exercises/exercise_194Pb_Exp_2025/New_TEline2022-ESR-194Pb-208Pb-nostripper_524MeV.lpp"
alphap = "1.4"
harmonics = "212"
refion = "194Pb+82"
circumference = "108.34"
mode = "Bρ"
value = "7.196596"
reload_data = true
nions = "100"
  43   Tue Apr 1 15:38:50 2025 ruijiu chenAnalysisfrequency drift
  15   Mon Mar 31 22:35:36 2025 ruijiu ChenAnalysisIdentification of 194Pb82
  40   Tue Apr 1 14:25:21 2025 ruijiu AnalysisThe frequency of 194Pb82+ has been changed from 408.606MHz to 408.602MHy during last 12 hours
The following images display the frequency spectrum at the start of every hour from 3:00 to 14:00.
  7   Mon Mar 31 14:59:18 2025 ruijiuAnalysisrun rionidgui program at HKR
At HKR, there is a Windows computer equipped with X2go software, which allows users to log in to the GPU computer. The login process is as follows: [login steps detailed below]. Once you 
have successfully logged into the GPU computer, you can run the rionid program to identify ions at HKR.
  18   Tue Apr 1 02:03:33 2025 ruijiuAnalysisThe frequency of 194Pb82+ has been changed from 408.522 MHz to 408.637 MHz
this is the new setting after we lost the old one.


datafile = "/data.local/G22-00018_00203/results/analyzers/RSA01/RSA01-2025.04.01.00.55.55.572.tiq_spectrum.npz"
filep = "/data.local/G22-00018_00203/scripts/OnlineDataAnalysisSystem/rionid_exercises/exercise_194Pb_Exp_2025/New_TEline2022-ESR-194Pb-208Pb-nostripper_524MeV.lpp"
alphap = "1.399"
harmonics = "211"
refion = "194Pb+82"
circumference = "108.34"
mode = "Frequency"
value = "408637000"
reload_data = true
nions = "100"
  19   Tue Apr 1 02:20:36 2025 ruijiuAnalysischange back the frequency of 194Pb82
frequency of 194Pb82+ at 211 408606000
frequency of 194Pb82+ at 126 244001000
  41   Tue Apr 1 14:54:24 2025 allGeneralNo SIS beam since 14:35
  204   Sat Apr 5 16:54:58 2025 ZsoltGeneral188Hf +72 setting back
The 188Hf72+ setting measurement starts now. Exactly the same setting like two days ago.