Entry  Wed Apr 9 06:47:51 2025, Esther, Nikos, General, Brief beam interruptions 2025-04-09_06-44-13-080_tcl1064.png2025-04-09_06-44-10-755_tcl1064.tdf
There was no beam from SIS between about 06:28 and 06:39.

Again from 07:02 to 07:11.

And again from 07:49 to 07:55.
Entry  Wed Apr 9 09:30:14 2025, Yuri, General, Slit changing 
I would like to close E01 slits a bit more and get 30 min of data with higher 
resolving power.

EEX scraper from -10 now -1
E01 unchanged
Entry  Wed Apr 9 10:08:08 2025, Nikos, Esther, General, Screenshots 2025-04-09_10-07-15-588_tcl1146.png2025-04-09_10-07-14-388_tcl1146.tdf2025-04-09_10-10-22-462.png
Lassie exports from the last morning shift + screenshot of Schottky TV after the last injection from SIS
Entry  Wed Apr 9 10:24:54 2025, Yuri, Sergey, Nikos, Esther, General, Final Injection 
The a final injection from SIS18 stored at 10:04.
The scrapers were moved out before to get the maximum intensity.
NTCAP is still running, the RSAs recorded the last files at 10:04.
The plan is to keep running like this for about an hour.
    Reply  Wed Apr 9 11:03:48 2025, Yuri, Sergey, Esther, General, Final Injection 
> The a final injection from SIS18 stored at 10:04.
> The scrapers were moved out before to get the maximum intensity.
> NTCAP is still running, the RSAs recorded the last files at 10:04.
> The plan is to keep running like this for about an hour.

Beam stopped at 10:58.
NTCAP and RSAs are stopped.
Entry  Wed Apr 9 11:09:48 2025, Wolfram, General, Thanks to everybody for their committment to perform this experiment  
 
Entry  Fri Apr 11 15:49:41 2025, Shahab, General, Screenshots of RSAs 11x
Screenshots of RSAs showing acquisition settings, for documentation, they show the time / date on the bottom left, in case needed for data analysis.
Entry  Fri Apr 11 15:57:37 2025, Shahab, General, More screenshots of RSAs 11x
more screen shots of RSAs.
Entry  Thu Mar 27 17:20:40 2025, Esther, Yue, Carlo, Zac, Shahab, Detectors, Setup Genesys 2025-03-27_17-19-33-724.png
We set up the Genesys. Channel map:

tr0:
IO1: Trigger MBS
IO2: Trigger NTCAP
IO3: None
IO4: Trigger RSA01
IO5: Trigger RSA02

tr1: 
None
Entry  Tue Apr 1 17:08:13 2025, JG, ID, MC, CG, Detectors, pleiades in position 
The pleiades detectors are now moved into a position which does not disturb the stored beam. 

inner detector: BGO
device: GE01DD2IG 
position: +20mm
scraping beam: not possible

outer detector: GAGG
device: GE01DD2AG
position: -55mm
scraping beam at: -45mm

These positions are fixed, i.e. not moving automatically.
Entry  Wed Apr 2 20:57:34 2025, Shahab, Detectors, 10GB cables for the DAQ rack 
We have been working together with IT on the speed of data transfer: with the new 10 GB interface we can now transfer data from NAS to Lustre with 400MB/s. From NAS to GPU Computer up to 700MB/s. All cables around the rack are now 10GB capable.
Entry  Thu Apr 3 08:02:04 2025, Team PLEIADES (JG, ID, CJG, MC), Detectors, Entering ESR for PLEIADES 
We are going to enter the ESR to check on the PLEIADES pocket detectors and install a nitrogen cooling.
Entry  Fri Apr 4 16:12:14 2025, Team PLEIADES, Detectors, Inserting both PLEIADES detectors 
We are inserting both PLEIADES detectors step-wise, one by one. Main beam should not be affected too long.
Entry  Fri Apr 4 17:13:12 2025, Team Pleiades, Detectors, PLEIADES detector out 
17:12 We moved the PLEIADES detector out, both are outside now (in parking position)
Entry  Sat Apr 5 12:22:12 2025, Team PLEIADES, Detectors, PLEIADES inside detector in 
12:23 moved PLEIADES inside detector in to 2mm.
Entry  Sat Apr 5 14:11:49 2025, Team PLEIADES, Detectors, Moving inside pocket detector 
14:12 We are moving the inside pocket out for a moment, change the bias
Entry  Sat Apr 5 14:55:21 2025, Team PLEIADES, Detectors, Moving detectors in again, to 20mm 
14:57 We are moving the inside pocket detector in again, this time to 20mm
Entry  Sat Apr 5 17:26:48 2025, Team PLEIADES, Detectors, Outside pocket "repair" 
We tried to convince the outside pocket to move, no success. We can hear the "hissing sound" of the pressurized air but no movement. Sergey tried to move it from the HKR, also no success. After that I tried to move it again from the Messhuette...and the "Out of tolerance" error message is gone, and the pocket seems to move. (We cannot confirm from inside because the ESR is already closed).
Guess the outside pocket got intimidated by Sergey and decided to get moving again... ;-)

We will take a bit more beam once the setting is stable, but try not to fry another detector.
Entry  Sat Apr 5 17:34:14 2025, Team PLEIADES, Detectors, Moving outside detector in  
17:35 Slowly moving PLEIADES outside detector (GE01DD2AG) in for some data. Clipping ions at -20mm. Leaving detector at -40mm for a few minutes.
Entry  Sat Apr 5 19:20:32 2025, Team PLEIADES, Detectors, Outside detector moved out again 
19:20 The outside and inside PLEIADES detectors are both moved back into their parking positions. Shifts should continue monitoring the leakage current on the mesycontrol screens and enter the values every 2h in the Google spreadsheet: