281
|
Mon Apr 7 17:07:33 2025 |
Team PLEIADES | Detectors | Moving OUTSIDE PLEIADES detector slowly in (and out) |
17:08 Tried to move outside particle detector (GE01DD2AG) in - it is stuck again :-(
17:18 Sergey tried to move it, now it moves again. Moved to -100 mm.
17:30 Moved detector to outside parking position |
306
|
Tue Apr 8 09:53:04 2025 |
Team PLEIADES | Detectors | Moving outside particle detector in for 20min |
9:53 Data taking with outside detector (GE01DD2AG) moved in to -110mm |
308
|
Tue Apr 8 10:13:51 2025 |
Team PLEIADES | Detectors | Moved outside particle detector back into parking position |
10:16 Moved outside particle detector back into parking position (-126mm) |
310
|
Tue Apr 8 11:37:13 2025 |
Team PLEIADES | Detectors | PLEIADES |
11:37 Outside particle detector (GE01DD2AG) moved in to -100mm to take data |
Attachment 1: 2025-04-08_11-38-37-375.png
|
|
311
|
Tue Apr 8 11:57:56 2025 |
Team PLEIADES | Detectors | Outside detector moved out |
12:00 Outside particle detector moved out to parking position again (-125 mm) |
9
|
Mon Mar 31 16:53:03 2025 |
Shahab | DAQ | stop and delete NTCAP data from Weekend test |
stop and delete NTCAP data from Weekend test
for now the NAS data2 bank has been flushed to make sure good operation for today's beam.
we have now 35 TB space on bank 2.
the recording will be done on the bank2 of the NAS.
There are still some junk data on bank1, which we will remove later. |
10
|
Mon Mar 31 17:46:21 2025 |
Esther | DAQ | NTCAP scaler assignment |
The setup contains two NI-6612 I/O cards with BNC-2121 connector accessories that provide eight inputs each for TTL scaler signals.
Important: When connecting scaler signals make sure that they are TTL (not NIM)!
Additionally, there is the possibility to assign data streams (eg clocks) from other modules in the NI chassis to scaler channels.
Below you find the assignment of the channels on the software side, including the internal clocks. This is important when analysing the .tmds files.
Channel | Input | Comment
|
0 | 10 MHz clock | external (from NI 6674T timing module)
|
1 | DC trafo | ion current in ESR
|
2 | injection trigger | from Genesys (IO2 on sddsc221)
|
3 | U-cooler | cooler voltage
|
4 | I-cooler | cooler electron current
|
5 | P-gun | pressure at e-cooler
|
6 | 100 kHz clock | internal
|
7 | 20 MHz clock | internal
|
8 | software trigger | from Detectomer
|
9 | PLEIADES outside |
|
9 | PLEIADES inside |
|
|
12
|
Mon Mar 31 20:53:02 2025 |
Shahab, Carlo, Zac, Esther, Michael | DAQ | DAQ start |
20:28 started NTCAP
started queqiao file transfer for RSAs only
started analyzer looper for RSAs
|
21
|
Tue Apr 1 02:55:06 2025 |
Shahab, Michael, Yue, Zac, Carlo | DAQ | new RSA recording |
anything from RSA01-2025.04.01.02.54.25.976.tiq onwards is good data
recording parameters:
5 MHz with 6.25 MSPS, 2.5 seconds, analyzer span 100 khz, trigger at 5%
All analyzer times are now set to summer time
file time stamps are correct
settings are in the attached pictures. |
Attachment 1: IMG_4955.JPG
|
|
Attachment 2: IMG_4956.JPG
|
|
Attachment 3: IMG_4954.JPG
|
|
23
|
Tue Apr 1 03:50:12 2025 |
Shahab, Yue, Carlo, Zac, Esther, Michael | DAQ | Tuners of the both cavities set |
410 MHz cavity resonance frequency tuned. motors both on 50 mm
245 MHz cavity resonance frequency tuned. motors both on 390 mm |
24
|
Tue Apr 1 03:52:56 2025 |
Shahab, Michael, Yue, Zac, Carlo | DAQ | good files |
all settings are done.
any files coming after this one is good:
RSA01-2025.04.01.03.52.59.247.tiq |
42
|
Tue Apr 1 15:32:59 2025 |
Zac | DAQ | NTCAP Restarted |
NTCAP Has been restarted (we restart every day around 15:00 so data goes in a new folder) |
50
|
Tue Apr 1 20:37:04 2025 |
Jeroen | DAQ | Change of settings for shorter acq. window |
Acquisition stopped at 20:36.
First file from this setting: RSA01-2025.04.01.03.52.59.247.tiq
Last file from this setting: RSA01-2025.04.01.20.36.54.257.tiq
acq. length changed to 500 ms
acq bw changed to 50 MHz
==> 12 MSamples
Trigger window condition set to 50%.
First file from this setting: RSA01-2025.04.01.20.45.40.053.tiq
Analysis setting the the frame length 2^16 and frame number = 190. |
51
|
Tue Apr 1 21:05:20 2025 |
Jeroen, Zac, Esther, Shahab, Wolfram | DAQ | Change of settings for shorter acq. window |
> Acquisition stopped at 20:36.
>
> First file from this setting: RSA01-2025.04.01.03.52.59.247.tiq
>
> Last file from this setting: RSA01-2025.04.01.20.36.54.257.tiq
>
> acq. length changed to 500 ms
>
> acq bw changed to 50 MHz
>
> ==> 12 MSamples
>
> Trigger window condition set to 50%.
>
> First file from this setting: RSA01-2025.04.01.20.45.40.053.tiq
>
> Analysis setting the the frame length 2^16 and frame number = 190.
Last file from previous setting: RSA01-2025.04.01.21.06.30.580.tiq
Changed the RSA01,02 to 50 MSamples/s (20nsec/sample) for 500.00 ms acq. length, 25 MHz acq. BW, 33% trigger position.
First good file from this time: 21:37 04.01.2025 -- RSA01-2025.04.01.21.37.13.721.tiq |
52
|
Tue Apr 1 22:03:07 2025 |
Jeroen, Zac, Esther, Shahab, Wolfram | DAQ | Optimisation of settings |
Estimation of potential gain by changing. Files from this points are going to rubbish. Potential gains are c. 20%
22:04: The current acquisition window is recording for 2.9 s. And is not recording for 3.9 s. We are running currently with a spill cycle of 5s every repetition.
22:22 The spill cycle between each injection was changed to 4->3->2s progressively and FRS also stopped taking spills so we settled on 2s spill request.
In the morning the spill request has to be changed back to 5s when the FRS goes back into operation.
new file with the setting is
RSA01-2025.04.01.22.19.06.761.tiq
[analysis]
nframes = 190
lframes = 65536
navg = 1 |
55
|
Tue Apr 1 23:07:15 2025 |
Shahab | DAQ | short interruption of queqiao script for RSAs |
has been restored. |
57
|
Tue Apr 1 23:56:18 2025 |
Shahab, Carlo, Zac, Yue, Michael | DAQ | Change of RSA01 settings for new harmonic=212. |
23:55 stop the RSAs.
410:
last file from previous setting (harmonic=211): 2025.04.01.23.55.21.712.
new plunger position for 410 cavity: 33.5 inside and outside.
new center frequency: 410535000 Hz.
245:
harmonic didn't change, still 126.
adjusted center frequency to 243997000 Hz.
00:31 restart the RSAs.
new files from: 2025.04.02.00.31.11.796. |
61
|
Wed Apr 2 02:51:31 2025 |
Carlo, Zac, Chris | DAQ | Beam is back |
02:44 beam is back |
62
|
Wed Apr 2 04:33:57 2025 |
Carlo, Zac, Chris | DAQ | Screenshots Lassie |
screenshots of Lassie |
Attachment 1: 2025-04-02_04-28-59-944_tcl1064.png
|
|
Attachment 2: 2025-04-02_03-38-54-877_tcl1064.png
|
|
65
|
Wed Apr 2 07:16:33 2025 |
Carlo, Chris, Alex, Michael | DAQ | ESR not requesting |
7:05 ESR not requesting new pulses from the SIS.
Operators are trying to fix the problem.
7:20 eam is back |