  masses & isomeres 2025, Page 14 of 17  Not logged in ELOG logo
ID Date Author Category Subjectdown Text Attachments
  117   Thu Apr 3 09:53:02 2025 Ruijiu Chen,WolframAnalysisGood injection ratioCurrently, we only use 37% of the injections
in our data analysis. However, 63% of the
injections have a height below 100, and these
 photo_2025-04-03_09-53-26.jpg 
  190   Sat Apr 5 11:37:44 2025 Ragan, Rui-Jiu, Zsolt, Wolfram, YuriGeneralGeneralWe have not seen 184Hf and 186Hf so far.    
  69   Wed Apr 2 07:41:10 2025 Michael, AlexGeneralFrequency shift in SchottkyAfter the beam  was restored at 07:25, we
think that the frequency peak in the 244
MHz RSA2 has jumped again (closer to the
  
  115   Thu Apr 3 09:34:42 2025 IDGeneralFinished in the ESR as of 9:05We had stopped the RSAs at 8:00 (call for
restart)
Time stamp computer stopped and started at
  
  326   Wed Apr 9 10:24:54 2025 Yuri, Sergey, Nikos, EstherGeneralFinal InjectionThe a final injection from SIS18 stored at
10:04.
The scrapers were moved out before to get
  
  327   Wed Apr 9 11:03:48 2025 Yuri, Sergey, EstherGeneralFinal Injection> The a final injection from SIS18 stored
at 10:04.
> The scrapers were moved out before to get
  
  90   Wed Apr 2 18:31:52 2025 IDGeneralFYI for morning shifts ThuThe PLEIADES team (pocket detectors) has discussed
with Wolfram to get access to the ESR tomorrow
(Thu) morning ~8:00 to check their detectors
  
  234   Sun Apr 6 14:17:07 2025 Ragan, Burcu, Gregor , Yuri, TakaGeneralEvery injection to the ESRFrom 14:15, we have every injection to the
ESR. FRS is on pause for 1-2 hours.
  
  114   Thu Apr 3 08:02:04 2025 Team PLEIADES (JG, ID, CJG, MC)DetectorsEntering ESR for PLEIADESWe are going to enter the ESR to check on
the PLEIADES pocket detectors and install
a nitrogen cooling.
  
  266   Mon Apr 7 10:40:33 2025 Team PLEIADESGeneralEnter ESRAt 10:45 we will enter the ESR and install
a remote oscilloscope for the PLEIADES outside
detector. Should take only 10 "GSI" minutes
  
  72   Wed Apr 2 09:28:59 2025 Michael, AlexGeneralEmpty injections in the ESRSince the FRS started to take the beam again,
the ESR gets 1/10 shots from SIS. But, the
ESR seems to request about twice more frequently
  
  147   Fri Apr 4 09:45:02 2025 Ragan, Wolfram, SergeyGeneralElectron CoolerRegina, Jan, and Markus are in the ESR to
check the electron cooler.
  
  149   Fri Apr 4 11:00:35 2025 Ragan, Wolfram, Sergey, ZsoltGeneralElectron CoolerElectron cooler anode voltage needs a repair
which might take 20-30 mins. If it takes
longer, we'll proceed without a cooler curve
  
  150   Fri Apr 4 11:15:05 2025 Ragan, Wolfram, Sergey, ZsoltGeneralElectron CoolerNo additional HV. So, have to proceed without
the cooler. 
Spare Power supply did not work either, we
  
  148   Fri Apr 4 10:36:40 2025 Ragan, Wolfram, Sergey, ZsoltGeneralESR setting change from 188Hf72+ to 186Hf72+ESR setting is changed from 188Hf72+ to 186Hf72+.
SIS-18 beam energy for the primary beam transmission
check is 528 MeV/u.
  
  161   Fri Apr 4 17:10:35 2025 H. Weick, S. LitvinovAcceleratorESR scraper settingthe new scraper setting for good isochronicity
but still acceptable intensity losses is:
Done at ~ 15:00 today.
  
  65   Wed Apr 2 07:16:33 2025 Carlo, Chris, Alex, MichaelDAQESR not requesting7:05 ESR not requesting new pulses from the
SIS. 
Operators are trying to fix the problem.
  
  73   Wed Apr 2 10:02:40 2025 Sergey + YuriAcceleratorESR TimeoutAt around 9:40, ESR timeout changed from 10
s to 30 s
Triggering only on real injections.
  
  275   Mon Apr 7 15:23:01 2025 Ragan, Wolfram, Sergey, Zsolt, Yuri, Rui-JiuGeneralESR Setting change to 192Pb82+Today, until 11 am, data were taken for the
188Hf setting. Since then, we are now tuning
on the 192Pb82+.
  
  282   Mon Apr 7 17:18:45 2025 Wolfram, Yuri, SergeyGeneralData from last 10 minutes are not useful (setting ESR)    