HOME ESR EXPERIMENTS LABS etc
E121 E127 E132 E125 E143 laser_cooling_2021 E142 Ê128 E146 E0052 E0018 E0028 E0038 E0075 E0203_E0018
  masses & isomeres 2025, Page 16 of 17  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
Entry  Tue Apr 1 03:52:56 2025, Shahab, Michael, Yue, Zac, Carlo, DAQ, good files 
all settings are done.
any files coming after this one is good:
Entry  Tue Apr 1 03:50:12 2025, Shahab, Yue, Carlo, Zac, Esther, Michael, DAQ, Tuners of the both cavities set 
410 MHz cavity resonance frequency tuned. motors both on 50 mm
245 MHz cavity resonance frequency tuned. motors both on 390 mm
Entry  Tue Apr 1 03:27:44 2025, Michael, General, Lassie Monitor 2025-04-01_03-22-05-395_tcl1064.png  2025-04-01_03-22-05-395_tcl1064.png
 
Entry  Tue Apr 1 02:55:06 2025, Shahab, Michael, Yue, Zac, Carlo, DAQ, new RSA recording IMG_4955.JPGIMG_4956.JPGIMG_4954.JPG
anything from RSA01-2025.04.01.02.54.25.976.tiq onwards is good data

recording parameters:
Entry  Tue Apr 1 02:37:28 2025, H. Weick, S. Litvinov, Accelerator, Isoc-setting +scrapers IMG_20250401_013626.jpgIMG_20250401_013636.jpgIMG_20250401_013646.jpgIMG_20250401_023358.jpg
First a setting with orbit bump for injection on central orbit was tried.
- quadrupoles tuned and scrapers optimized
Entry  Tue Apr 1 02:20:36 2025, ruijiu, Analysis, change back the frequency of 194Pb82 Screenshot_2025-04-01_02-20-09.png
frequency of 194Pb82+ at 211 408606000
frequency of 194Pb82+ at 126 244001000
Entry  Tue Apr 1 02:03:33 2025, ruijiu, Analysis, The frequency of 194Pb82+ has been changed from 408.522 MHz to 408.637 MHz Screenshot_2025-04-01_02-03-14.png
this is the new setting after we lost the old one.

Entry  Tue Apr 1 02:01:06 2025, Zac, Shahab, Ruijiu, Yuri, Sergey, Wolfram, Carlo, Michael, Accelerator, Settings lost 
Settings lost after the beam was lost. Trying to recover particle identification now that beam has returned.
Entry  Mon Mar 31 23:34:58 2025, ruijiu, shahab, yuri, wolfram, sergey, Analysis, identificaton of 194Pb82+ 8x
datafile = "/data.local/G22-00018_00203/results/analyzers/RSA01/RSA01-2025.03.31.22.18.16.965.tiq_spectrum.npz"
filep = "/data.local/G22-00018_00203/scripts/OnlineDataAnalysisSystem/rionid_exercises/exercise_194Pb_Exp_2025/New_TEline2022-ESR-194Pb-208Pb-nostripper_524MeV.lpp"
alphap = "1.4"
Entry  Mon Mar 31 22:35:36 2025, ruijiu Chen, Analysis, Identification of 194Pb82 7x
 
Entry  Mon Mar 31 22:13:04 2025, Shahab, Yue, Carlo, Zac, Esther, Runs, PID continued photo_2025-03-31_22-17-30.jpg
continuing PID with better / higher resolution:

RSA01-2025.03.31.21.10.54.758.tiq_spectrum.npz
Entry  Mon Mar 31 22:03:56 2025, Shahab, Yue, Carlo, Zac, Esther, Runs, PID 
trying to do PID with some injections:

RSAs are still on winter time. they show summer time but files have winter time.
Entry  Mon Mar 31 20:53:02 2025, Shahab, Carlo, Zac, Esther, Michael, DAQ, DAQ start 
20:28 started NTCAP
started queqiao file transfer for RSAs only
started analyzer looper for RSAs
Entry  Mon Mar 31 20:42:38 2025, H. Weick, S. Litvinov, Accelerator, fragment setting, E-SIS 
~ 20:00 changed E-SIS to 524.0 MeV/u to get 194Pb at the Brho of the primary beam before (=7.2008 Tm).
which corresponds to gamma = 1.400 for 194Pb82+. 
Before it was E-SIS = 480.5 MeV/u after Be-1839 mg/m^2 target Brho = 7.2014 Tm.
Entry  Mon Mar 31 17:46:21 2025, Esther, DAQ, NTCAP scaler assignment 
The setup contains two NI-6612 I/O cards with BNC-2121 connector accessories that provide eight inputs each for TTL scaler signals. 
[B]Important: When connecting scaler signals make sure that they are TTL (not NIM)![/B]
Entry  Mon Mar 31 16:53:03 2025, Shahab, DAQ, stop and delete NTCAP data from Weekend test 
stop and delete NTCAP data from Weekend test

for now the NAS data2 bank has been flushed to make sure good operation for today's beam.
Entry  Mon Mar 31 16:05:48 2025, ruijiu, shahab, yuyue, zac, carlo, ersther, Analysis, check the trigger signal in the scaler data of NTCAP Screenshot_20250331_161004.pngScreenshot_2025-03-31_16-23-55.png
1. convert copy a tdms file into the folder:
(pyroot) gpuuser@appc256:/data.local/G22-00018_00203/data/ntcap/sc/SC_2025-03-28_18-48-51$ cp /mnt/ntcap-data2/G22-00018_00203/data/ntcap/sc/SC_2025-03-28_18-
48-51/0000216.sc.tdms ./
Entry  Mon Mar 31 14:59:18 2025, ruijiu, Analysis, run rionidgui program at HKR IMG_20250331_150222.jpgIMG_20250331_150216.jpgIMG_20250331_151940.jpgIMG_20250331_151929.jpgIMG_20250331_151959.jpg
At HKR, there is a Windows computer equipped with X2go software, which allows users to log in to the GPU computer. The login process is as follows: [login
steps detailed below]. Once you 
have successfully logged into the GPU computer, you can run the rionid program to identify ions at HKR.
Entry  Mon Mar 31 10:46:43 2025, Ruijiu Chen, Analysis, This program is used to combine spectrum which is recored by RSA into one spectrum. generate_data_1.sh
This program is used to combine spectrum of many injections into one spectrum.

Example of usage:
Entry  Fri Mar 28 22:20:47 2025, Sergey, Shahab, General, Pattern pattern.JPG
the ACC pattern for both experiments.
ELOG V3.1.5-fc6679b