Tue Apr 1 03:52:56 2025, Shahab, Michael, Yue, Zac, Carlo, DAQ, good files
|
all settings are done.
any files coming after this one is good:
RSA01-2025.04.01.03.52.59.247.tiq |
Tue Apr 1 03:50:12 2025, Shahab, Yue, Carlo, Zac, Esther, Michael, DAQ, Tuners of the both cavities set
|
410 MHz cavity resonance frequency tuned. motors both on 50 mm
245 MHz cavity resonance frequency tuned. motors both on 390 mm |
Tue Apr 1 03:27:44 2025, Michael, General, Lassie Monitor 2025-04-01_03-22-05-395_tcl1064.png
|
|
Tue Apr 1 02:55:06 2025, Shahab, Michael, Yue, Zac, Carlo, DAQ, new RSA recording  
|
anything from RSA01-2025.04.01.02.54.25.976.tiq onwards is good data
recording parameters:
5 MHz with 6.25 MSPS, 2.5 seconds, analyzer span 100 khz, trigger at 5%
All analyzer times are now set to summer time
file time stamps are correct
settings are in the attached pictures. |
Tue Apr 1 02:37:28 2025, H. Weick, S. Litvinov, Accelerator, Isoc-setting +scrapers   
|
First a setting with orbit bump for injection on central orbit was tried.
- quadrupoles tuned and scrapers optimized
Then back to an ESR setting without this bump like last year.
- again quadrupoles tuned and scrapers optimized
This gave a good resolution in which the isomer should be resolved.
Just after this was achieved all resolution was lost.
Making the input for ESR setting again recovered it, now with slightly different scrapers.
Quads: K'L Q3D / Q6D = -0.3603263
Sext: K''L GE01KS2 = -0.14
GE01KS3 = 0.05
scrapers: GEEXDS1HA = -5 mm
GE01DS3HG = -70 mm
Details see paper scans below. |
Tue Apr 1 02:20:36 2025, ruijiu, Analysis, change back the frequency of 194Pb82
|
frequency of 194Pb82+ at 211 408606000
frequency of 194Pb82+ at 126 244001000 |
Tue Apr 1 02:03:33 2025, ruijiu, Analysis, The frequency of 194Pb82+ has been changed from 408.522 MHz to 408.637 MHz
|
this is the new setting after we lost the old one.
datafile = "/data.local/G22-00018_00203/results/analyzers/RSA01/RSA01-2025.04.01.00.55.55.572.tiq_spectrum.npz"
filep = "/data.local/G22-00018_00203/scripts/OnlineDataAnalysisSystem/rionid_exercises/exercise_194Pb_Exp_2025/New_TEline2022-ESR-194Pb-208Pb-nostripper_524MeV.lpp"
alphap = "1.399"
harmonics = "211"
refion = "194Pb+82"
circumference = "108.34"
mode = "Frequency"
value = "408637000"
reload_data = true
nions = "100" |
Tue Apr 1 02:01:06 2025, Zac, Shahab, Ruijiu, Yuri, Sergey, Wolfram, Carlo, Michael, Accelerator, Settings lost
|
Settings lost after the beam was lost. Trying to recover particle identification now that beam has returned. |
Mon Mar 31 23:34:58 2025, ruijiu, shahab, yuri, wolfram, sergey, Analysis, identificaton of 194Pb82+ 8x
|
datafile = "/data.local/G22-00018_00203/results/analyzers/RSA01/RSA01-2025.03.31.22.18.16.965.tiq_spectrum.npz"
filep = "/data.local/G22-00018_00203/scripts/OnlineDataAnalysisSystem/rionid_exercises/exercise_194Pb_Exp_2025/New_TEline2022-ESR-194Pb-208Pb-nostripper_524MeV.lpp"
alphap = "1.4"
harmonics = "212"
refion = "194Pb+82"
circumference = "108.34"
mode = "Bρ"
value = "7.196596"
reload_data = true
nions = "100" |
Mon Mar 31 22:35:36 2025, ruijiu Chen, Analysis, Identification of 194Pb82 7x
|
|
Mon Mar 31 22:13:04 2025, Shahab, Yue, Carlo, Zac, Esther, Runs, PID continued
|
continuing PID with better / higher resolution:
RSA01-2025.03.31.21.10.54.758.tiq_spectrum.npz
...
RSA01-2025.03.31.21.12.29.106.tiq_spectrum.npz
trying to do PID.... |
Mon Mar 31 22:03:56 2025, Shahab, Yue, Carlo, Zac, Esther, Runs, PID
|
trying to do PID with some injections:
RSAs are still on winter time. they show summer time but files have winter time.
data used for PID is range from:
RSA01-2025.03.31.20.21.13.217.tiq_spectrum.npz
...
RSA01-2025.03.31.20.53.06.492.tiq_spectrum.npz
gamma_t = 1.4
but files are not so good. |
Mon Mar 31 20:53:02 2025, Shahab, Carlo, Zac, Esther, Michael, DAQ, DAQ start
|
20:28 started NTCAP
started queqiao file transfer for RSAs only
started analyzer looper for RSAs
|
Mon Mar 31 20:42:38 2025, H. Weick, S. Litvinov, Accelerator, fragment setting, E-SIS
|
~ 20:00 changed E-SIS to 524.0 MeV/u to get 194Pb at the Brho of the primary beam before (=7.2008 Tm).
which corresponds to gamma = 1.400 for 194Pb82+.
Before it was E-SIS = 480.5 MeV/u after Be-1839 mg/m^2 target Brho = 7.2014 Tm.
Keep target and beamlines and ESR the same, only SIS and TE-line before target is changed. |
Mon Mar 31 17:46:21 2025, Esther, DAQ, NTCAP scaler assignment
|
The setup contains two NI-6612 I/O cards with BNC-2121 connector accessories that provide eight inputs each for TTL scaler signals.
Important: When connecting scaler signals make sure that they are TTL (not NIM)!
Additionally, there is the possibility to assign data streams (eg clocks) from other modules in the NI chassis to scaler channels.
Below you find the assignment of the channels on the software side, including the internal clocks. This is important when analysing the .tmds files.
Channel | Input | Comment
|
0 | 10 MHz clock | external (from NI 6674T timing module)
|
1 | DC trafo | ion current in ESR
|
2 | injection trigger | from Genesys (IO2 on sddsc221)
|
3 | U-cooler | cooler voltage
|
4 | I-cooler | cooler electron current
|
5 | P-gun | pressure at e-cooler
|
6 | 100 kHz clock | internal
|
7 | 20 MHz clock | internal
|
8 | software trigger | from Detectomer
|
9 | PLEIADES outside |
|
9 | PLEIADES inside |
|
|
Mon Mar 31 16:53:03 2025, Shahab, DAQ, stop and delete NTCAP data from Weekend test
|
stop and delete NTCAP data from Weekend test
for now the NAS data2 bank has been flushed to make sure good operation for today's beam.
we have now 35 TB space on bank 2.
the recording will be done on the bank2 of the NAS.
There are still some junk data on bank1, which we will remove later. |
Mon Mar 31 16:05:48 2025, ruijiu, shahab, yuyue, zac, carlo, ersther, Analysis, check the trigger signal in the scaler data of NTCAP 
|
1. convert copy a tdms file into the folder:
(pyroot) gpuuser@appc256:/data.local/G22-00018_00203/data/ntcap/sc/SC_2025-03-28_18-48-51$ cp /mnt/ntcap-data2/G22-00018_00203/data/ntcap/sc/SC_2025-03-28_18-
48-51/0000216.sc.tdms ./
2. convert the tdms file into root file.
(pyroot) gpuuser@appc256:/data.local/G22-00018_00203/data/ntcap/sc/SC_2025-03-28_18-48-51$ /data.local/G22-
00018_00203/scripts/OnlineDataAnalysisSystem/iqt7/convert_iqt_sc -i 0000216.sc.tdms -o ./
3. plot the result.
picture 1,2: trigger vs time
picture 3: solfware trigger vs time |
Mon Mar 31 14:59:18 2025, ruijiu, Analysis, run rionidgui program at HKR    
|
At HKR, there is a Windows computer equipped with X2go software, which allows users to log in to the GPU computer. The login process is as follows: [login steps detailed below]. Once you
have successfully logged into the GPU computer, you can run the rionid program to identify ions at HKR. |
Mon Mar 31 10:46:43 2025, Ruijiu Chen, Analysis, This program is used to combine spectrum which is recored by RSA into one spectrum.
|
This program is used to combine spectrum of many injections into one spectrum.
Example of usage:
(pyroot) gpuuser@appc256:/data.local/G22-00018_00203/scripts/OnlineDataAnalysisSystem/shift/20250331/data$ bash generate_data.sh /data.local/G22-00018_00203/results/analyzers/RSA01 RSA01-
'*.tiq_spectrogram.npz' 2025.04.01.04.00.00.000 2025.04.01.19.00.00.000 0.001 408590000 408620000 0.3 |
Fri Mar 28 22:20:47 2025, Sergey, Shahab, General, Pattern
|
the ACC pattern for both experiments. |