Entry  Tue Apr 1 03:52:56 2025, Shahab, Michael, Yue, Zac, Carlo, DAQ, good files 
all settings are done.
any files coming after this one is good:

RSA01-2025.04.01.03.52.59.247.tiq
Entry  Tue Apr 1 03:50:12 2025, Shahab, Yue, Carlo, Zac, Esther, Michael, DAQ, Tuners of the both cavities set 
410 MHz cavity resonance frequency tuned. motors both on 50 mm
245 MHz cavity resonance frequency tuned. motors both on 390 mm
Entry  Tue Apr 1 03:27:44 2025, Michael, General, Lassie Monitor 2025-04-01_03-22-05-395_tcl1064.png  2025-04-01_03-22-05-395_tcl1064.png
 
Entry  Tue Apr 1 02:55:06 2025, Shahab, Michael, Yue, Zac, Carlo, DAQ, new RSA recording IMG_4955.JPGIMG_4956.JPGIMG_4954.JPG
anything from RSA01-2025.04.01.02.54.25.976.tiq onwards is good data

recording parameters:

5 MHz with 6.25 MSPS, 2.5 seconds, analyzer span 100 khz, trigger at 5%

All analyzer times are now set to summer time
file time stamps are correct

settings are in the attached pictures.
Entry  Tue Apr 1 02:37:28 2025, H. Weick, S. Litvinov, Accelerator, Isoc-setting +scrapers IMG_20250401_013626.jpgIMG_20250401_013636.jpgIMG_20250401_013646.jpgIMG_20250401_023358.jpg
First a setting with orbit bump for injection on central orbit was tried.
- quadrupoles tuned and scrapers optimized

Then back to an ESR setting without this bump like last year.
- again quadrupoles tuned and scrapers optimized
This gave a good resolution in which the isomer should be resolved.

Just after this was achieved all resolution was lost.
Making the input for ESR setting again recovered it, now with slightly different scrapers.

Quads: K'L Q3D / Q6D = -0.3603263
Sext: K''L GE01KS2 = -0.14
           GE01KS3 =  0.05

scrapers: GEEXDS1HA =  -5 mm
          GE01DS3HG = -70 mm 

Details see paper scans below.
Entry  Tue Apr 1 02:20:36 2025, ruijiu, Analysis, change back the frequency of 194Pb82 Screenshot_2025-04-01_02-20-09.png
frequency of 194Pb82+ at 211 408606000
frequency of 194Pb82+ at 126 244001000
Entry  Tue Apr 1 02:03:33 2025, ruijiu, Analysis, The frequency of 194Pb82+ has been changed from 408.522 MHz to 408.637 MHz Screenshot_2025-04-01_02-03-14.png
this is the new setting after we lost the old one.


datafile = "/data.local/G22-00018_00203/results/analyzers/RSA01/RSA01-2025.04.01.00.55.55.572.tiq_spectrum.npz"
filep = "/data.local/G22-00018_00203/scripts/OnlineDataAnalysisSystem/rionid_exercises/exercise_194Pb_Exp_2025/New_TEline2022-ESR-194Pb-208Pb-nostripper_524MeV.lpp"
alphap = "1.399"
harmonics = "211"
refion = "194Pb+82"
circumference = "108.34"
mode = "Frequency"
value = "408637000"
reload_data = true
nions = "100"
Entry  Tue Apr 1 02:01:06 2025, Zac, Shahab, Ruijiu, Yuri, Sergey, Wolfram, Carlo, Michael, Accelerator, Settings lost 
Settings lost after the beam was lost. Trying to recover particle identification now that beam has returned.
Entry  Mon Mar 31 23:34:58 2025, ruijiu, shahab, yuri, wolfram, sergey, Analysis, identificaton of 194Pb82+ 8x
datafile = "/data.local/G22-00018_00203/results/analyzers/RSA01/RSA01-2025.03.31.22.18.16.965.tiq_spectrum.npz"
filep = "/data.local/G22-00018_00203/scripts/OnlineDataAnalysisSystem/rionid_exercises/exercise_194Pb_Exp_2025/New_TEline2022-ESR-194Pb-208Pb-nostripper_524MeV.lpp"
alphap = "1.4"
harmonics = "212"
refion = "194Pb+82"
circumference = "108.34"
mode = "Bρ"
value = "7.196596"
reload_data = true
nions = "100"
Entry  Mon Mar 31 22:35:36 2025, ruijiu Chen, Analysis, Identification of 194Pb82 7x
 
Entry  Mon Mar 31 22:13:04 2025, Shahab, Yue, Carlo, Zac, Esther, Runs, PID continued photo_2025-03-31_22-17-30.jpg
continuing PID with better / higher resolution:

RSA01-2025.03.31.21.10.54.758.tiq_spectrum.npz
...
RSA01-2025.03.31.21.12.29.106.tiq_spectrum.npz

trying to do PID....
Entry  Mon Mar 31 22:03:56 2025, Shahab, Yue, Carlo, Zac, Esther, Runs, PID 
trying to do PID with some injections:

RSAs are still on winter time. they show summer time but files have winter time.

data used for PID is range from:

RSA01-2025.03.31.20.21.13.217.tiq_spectrum.npz
...
RSA01-2025.03.31.20.53.06.492.tiq_spectrum.npz

gamma_t = 1.4

but files are not so good.
Entry  Mon Mar 31 20:53:02 2025, Shahab, Carlo, Zac, Esther, Michael, DAQ, DAQ start 
20:28 started NTCAP
started queqiao file transfer for RSAs only
started analyzer looper for RSAs

 
Entry  Mon Mar 31 20:42:38 2025, H. Weick, S. Litvinov, Accelerator, fragment setting, E-SIS 
~ 20:00 changed E-SIS to 524.0 MeV/u to get 194Pb at the Brho of the primary beam before (=7.2008 Tm).
which corresponds to gamma = 1.400 for 194Pb82+. 
Before it was E-SIS = 480.5 MeV/u after Be-1839 mg/m^2 target Brho = 7.2014 Tm.
Keep target and beamlines and ESR the same, only SIS and TE-line before target is changed.
Entry  Mon Mar 31 17:46:21 2025, Esther, DAQ, NTCAP scaler assignment 
The setup contains two NI-6612 I/O cards with BNC-2121 connector accessories that provide eight inputs each for TTL scaler signals.
Important: When connecting scaler signals make sure that they are TTL (not NIM)!

Additionally, there is the possibility to assign data streams (eg clocks) from other modules in the NI chassis to scaler channels.
Below you find the assignment of the channels on the software side, including the internal clocks. This is important when analysing the .tmds files.

ChannelInputComment
010 MHz clockexternal (from NI 6674T timing module)
1DC trafoion current in ESR
2injection triggerfrom Genesys (IO2 on sddsc221)
3U-coolercooler voltage
4I-coolercooler electron current
5P-gunpressure at e-cooler
6100 kHz clockinternal
720 MHz clockinternal
8software triggerfrom Detectomer
9PLEIADES outside
9PLEIADES inside
Entry  Mon Mar 31 16:53:03 2025, Shahab, DAQ, stop and delete NTCAP data from Weekend test 
stop and delete NTCAP data from Weekend test

for now the NAS data2 bank has been flushed to make sure good operation for today's beam.
we have now 35 TB space on bank 2.

the recording will be done on the bank2 of the NAS.

There are still some junk data on bank1, which we will remove later.
Entry  Mon Mar 31 16:05:48 2025, ruijiu, shahab, yuyue, zac, carlo, ersther, Analysis, check the trigger signal in the scaler data of NTCAP Screenshot_20250331_161004.pngScreenshot_2025-03-31_16-23-55.png
1. convert copy a tdms file into the folder:
(pyroot) gpuuser@appc256:/data.local/G22-00018_00203/data/ntcap/sc/SC_2025-03-28_18-48-51$ cp /mnt/ntcap-data2/G22-00018_00203/data/ntcap/sc/SC_2025-03-28_18-
48-51/0000216.sc.tdms ./
2. convert the tdms file into root file.
(pyroot) gpuuser@appc256:/data.local/G22-00018_00203/data/ntcap/sc/SC_2025-03-28_18-48-51$ /data.local/G22-
00018_00203/scripts/OnlineDataAnalysisSystem/iqt7/convert_iqt_sc -i 0000216.sc.tdms  -o ./
3. plot the result.
picture 1,2: trigger vs time
picture 3: solfware trigger vs time
Entry  Mon Mar 31 14:59:18 2025, ruijiu, Analysis, run rionidgui program at HKR IMG_20250331_150222.jpgIMG_20250331_150216.jpgIMG_20250331_151940.jpgIMG_20250331_151929.jpgIMG_20250331_151959.jpg
At HKR, there is a Windows computer equipped with X2go software, which allows users to log in to the GPU computer. The login process is as follows: [login steps detailed below]. Once you 
have successfully logged into the GPU computer, you can run the rionid program to identify ions at HKR.
Entry  Mon Mar 31 10:46:43 2025, Ruijiu Chen, Analysis, This program is used to combine spectrum which is recored by RSA into one spectrum. generate_data_1.sh
This program is used to combine spectrum of many injections into one spectrum.

Example of usage:

(pyroot) gpuuser@appc256:/data.local/G22-00018_00203/scripts/OnlineDataAnalysisSystem/shift/20250331/data$ bash generate_data.sh /data.local/G22-00018_00203/results/analyzers/RSA01 RSA01- 
'*.tiq_spectrogram.npz' 2025.04.01.04.00.00.000 2025.04.01.19.00.00.000 0.001 408590000 408620000 0.3
Entry  Fri Mar 28 22:20:47 2025, Sergey, Shahab, General, Pattern pattern.JPG
the ACC pattern for both experiments.