HOME ESR EXPERIMENTS LABS etc
E121 E127 E132 E125 E143 laser_cooling_2021 E142 Ê128 E146 E0052 E0018 E0028 E0038 E0075 E0203_E0018
  masses & isomeres 2025, Page 17 of 17  Not logged in ELOG logo
Entry  Fri Apr 4 23:33:51 2025, Ruijiu Chen, Analysis, Analysis during April 4th 16:00-22:00 photo_2025-04-04_23-34-49.jpgphoto_2025-04-04_23-35-29.jpgphoto_2025-04-04_23-35-52.jpgphoto_2025-04-04_23-36-12.jpgsummed_spectrum_total_April04_1600_2200.npz
Until now, there is no 184Hf72+ and 186Hf72+ ions. 
Entry  Sun Apr 6 22:53:53 2025, Michael, Analysis, Added shift tracking and power threshold to Shahab's npz_addup.py 
I added automatic shift tracking and a check for a minimum wanted power in that bin to Shahab's npz_addup.py script.
It looks for the highest bin in the projected spectrum (so after time-cut) and tracks it position. Careful, it uses the position in the very first FILE
as reference. So, the ordering in the given file list affects this.
Entry  Sun Apr 6 17:29:04 2025, Ruijiu Chen, Analysis, 188Hf72+ spectrum and single ion line from NTCAP data photo_2025-04-06_17-30-36.jpgphoto_2025-04-06_17-30-59.jpgphoto_2025-04-06_17-32-55.jpgphoto_2025-04-06_17-33-27.jpg
This shows the spectrum of 188Hf72+ during "April06_01:00_02:00". Until April 6 2:00, the Bp = 7.918262 Tm has not been changed. 
The ntcap spectrum is from:
/data.local/G22-00018_00203/results/ntcap/iq/IQ_2025-04-05_17-43-49/0000756.iq.tdms.root
Entry  Sat Apr 5 16:48:26 2025, Ragan, Wolfram, Sergey, Zsolt, Yuri, Rui-Jiu, General, 188Hf72+ 
Now ESR is set to the 188Hf72+ setting.
Entry  Thu Apr 3 13:36:17 2025, Ruijiu,Yuri, Wolfram,Zsolt, Analysis, 188Hf identification Screenshot_2025-04-03_15-19-47.pngScreenshot_2025-04-03_15-21-53_1.pngScreenshot_2025-04-03_15-23-37.pngsimulation_result.outScreenshot_2025-04-03_15-41-11.png
 
Entry  Sat Apr 5 16:54:58 2025, Zsolt, General, 188Hf +72 setting back 
The 188Hf72+ setting measurement starts now. Exactly the same setting like two days ago.
Entry  Fri Apr 4 16:01:09 2025, ID, MC, Kanika, General, 186Hf running now + Lassie screenshots 2025-04-04_16-03-30-165.png2025-04-04_16-03-16-249.png2025-04-04_16-02-19-195.png
Tuning is finished, 186Hf is running. Sharp peaks now.
Entry  Fri Apr 4 17:59:33 2025, Zac , Sid, DAQ, 17:58 
DAQ stopped with last file in RSA1-2025.04.04.17.58.49.340.tiq

Now the plan is to change one of the analyzers to narrow band recording for longer from the 245 Schotkky. 
Entry  Wed Apr 2 20:57:34 2025, Shahab, Detectors, 10GB cables for the DAQ rack 
We have been working together with IT on the speed of data transfer: with the new 10 GB interface we can now transfer data from NAS to Lustre with 400MB/s.
From NAS to GPU Computer up to 700MB/s. All cables around the rack are now 10GB capable.
Entry  Fri Apr 4 11:44:31 2025, Ragan, Wolfram, Sergey, Zsolt, Magda, General, ESR setting change from 188Hf72+ to 186Hf72+  
ESR setting is changed from 188Hf72+ to 186Hf72+. SIS-18 beam energy for 
this fragment is 510 MeV/u.Brho = 7.86166 Tm.
ELOG V3.1.5-fc6679b