  321   Tue Apr 8 23:08:15 2025 Sergey Litvinov, Xinliang YanGeneralTuning of the ion optics
From roughly 10:45 pm to 11:05 pm,  Sergey tuned the 
ion optics of the ESR to see if the mass resolution at 
413.55735 MHz improves or not. Please note that the 
frequencies of ions during the tuning process are not 
stable.

Q-magnets and S-magnets have been adjusted, see 
accelerator E-logs ID-844 titled ‘ ESR seting for 
204Pt77+’ created by Sergey.
  272   Mon Apr 7 13:18:27 2025 Jelena, GuyGeneralTuning
Beam was gone at 13:04 due to fragment tuning.
  23   Tue Apr 1 03:50:12 2025 Shahab, Yue, Carlo, Zac, Esther, MichaelDAQTuners of the both cavities set
410 MHz cavity resonance frequency tuned. motors both on 50 mm
245 MHz cavity resonance frequency tuned. motors both on 390 mm
  315   Tue Apr 8 13:46:20 2025 Michael GeneralTrying new Sextupole settings, all data after 13:44 affected
  6   Mon Mar 31 10:46:43 2025 Ruijiu ChenAnalysisThis program is used to combine spectrum which is recored by RSA into one spectrum.
This program is used to combine spectrum of many injections into one spectrum.

Example of usage:

(pyroot) gpuuser@appc256:/data.local/G22-00018_00203/scripts/OnlineDataAnalysisSystem/shift/20250331/data$ bash generate_data.sh /data.local/G22-00018_00203/results/analyzers/RSA01 RSA01- 
'*.tiq_spectrogram.npz' 2025.04.01.04.00.00.000 2025.04.01.19.00.00.000 0.001 408590000 408620000 0.3
  86   Wed Apr 2 17:46:12 2025 Ruijiu, Wolfram, Xinliang, WangqianAnalysisThe spectrum of 194Pb82+ vs 184Pt78+
In summary, the statistical results collected between 5:00 and 12:00 AM on April 2, 2025. For each injection, we calculate the frequency mean value 
(f_mean) and the peak height (P) of 194Pb ions for frames with t > 0.14 s, correct each injection’s frequency by subtracting f_mean, and only sum 
the 
spectra from injections with P > 100; moreover, by comparing the 194Pb82+ spectrum with that of 184Pt78+—whose isomer at 1.8 MeV (T1/2 = 1 ms) is 
clearly visible—the setup is demonstrated to be suitable for detecting an isomer with a lifetime of about 1 ms.
===================================================================
How to dod analysis and plot this result:
1. Add up injections and create accumulated spectrum.
(pyroot) gpuuser@appc256:/data.local/G22-00018_00203/scripts/OnlineDataAnalysisSystem/shift/20250331/data$ sh generate_data.sh /data.local/G22-
00018_00203/results/analyzers/RSA01 RSA01- 
'*.tiq_spectrogram.npz' 2025.04.02.05.00.00.000 2025.04.02.12.00.00.000 0.001 408.59e6 408.62e6 0.1 1

After run this command, you will create the accumulated spectrum under the folder with time stamp of start time and stop time.

2. Download the code "plot_fft.cxx" and plot the spectrum with following command:
...2025.04.02.05.00.00.000_2025.04.02.12.00.00.000$ root
   ------------------------------------------------------------------
  | Welcome to ROOT 6.32.10                        https://root.cern |
  | (c) 1995-2024, The ROOT Team; conception: R. Brun, F. Rademakers |
  | Built for linuxx8664gcc on Feb 12 2025, 01:50:41                 |
  | From tags/6-32-10@6-32-10                                        |
  | With                                                             |
  | Try '.help'/'.?', '.demo', '.license', '.credits', '.quit'/'.q'  |
   ------------------------------------------------------------------

root [0] .L plot_fft.cxx
root [1] plot_fft("2025.4.2 5:00~12:00",411.14e6,411.18e6,0,100)
  45   Tue Apr 1 16:47:32 2025 Ruijiu, Jan, ShahabAnalysisThe frequency of 194Pb82+ is changed to 408.600 MHz
  40   Tue Apr 1 14:25:21 2025 ruijiu AnalysisThe frequency of 194Pb82+ has been changed from 408.606MHz to 408.602MHy during last 12 hours
The following images display the frequency spectrum at the start of every hour from 3:00 to 14:00.
  18   Tue Apr 1 02:03:33 2025 ruijiuAnalysisThe frequency of 194Pb82+ has been changed from 408.522 MHz to 408.637 MHz
this is the new setting after we lost the old one.


datafile = "/data.local/G22-00018_00203/results/analyzers/RSA01/RSA01-2025.04.01.00.55.55.572.tiq_spectrum.npz"
filep = "/data.local/G22-00018_00203/scripts/OnlineDataAnalysisSystem/rionid_exercises/exercise_194Pb_Exp_2025/New_TEline2022-ESR-194Pb-208Pb-nostripper_524MeV.lpp"
alphap = "1.399"
harmonics = "211"
refion = "194Pb+82"
circumference = "108.34"
mode = "Frequency"
value = "408637000"
reload_data = true
nions = "100"
  77   Wed Apr 2 11:09:42 2025 Michael, AlexAcceleratorThe beam is back in the ESR
We have the beam again the ESR since around 11:00.
The Schottky spectra look the same as before.
The ESR experts could not exactly identify the problem which caused this loss of the beam.
  75   Wed Apr 2 10:31:15 2025 Michael, AlexAcceleratorThe beam is back from 10:10
  68   Wed Apr 2 07:39:41 2025 Michael, AlexGeneralThe beam is back at 07:35
  71   Wed Apr 2 08:47:27 2025 Michael, AlexGeneralThe beam is back
The beam is back. But, the experts have found a problem with one of the modules of the SIS kicker magnet. And, currently they have disabled this module. This fixed the problem. However, since the kicker system is not running with full power, it is not clear by how much this can affect the extracted beam intensity for the ESR. Therefore,  the ESR experts have been called and they will look at the injected beam intensity in the ring, in order to know if its still the same as before disabling the module. 
The experts will discuss at the upcoming meeting how to proceed with the damaged module, i.e. when to repair it.
In addition, the FRS started to take the beam now (again) which means that we will be getting less pulses from SIS as compared to the previous night.
  328   Wed Apr 9 11:09:48 2025 WolframGeneralThanks to everybody for their committment to perform this experiment
  33   Tue Apr 1 10:03:56 2025 Jelena B, SiddharthGeneralTechnical issue with SIS18
From HKR info: there is a technical issue with SIS18 and we will have no beam for next 25 minutes. 
  116   Thu Apr 3 09:43:14 2025 AllAcceleratorStop 194Pb, switch to 208Pb82+
The repair of SIS electron cooler power supplies

In the meantime we received a few injections and confirmed that 194Pb setting is still as it was before entering into the ESR

Now we change to 208Pb82+ to do several ESR accelerator tests

Esis = 517 MeV/u
Change the beamline to 208 Pb 82+ and the ESR to 208 b 82+ and NO other changes
  82   Wed Apr 2 15:07:52 2025 Michael, Alex, MaeveAcceleratorStill not a good beam in the ESR
The (power supply of) SIS kicker magnet has been repaired and the beam has been restored from about 14:20.
But, the Schottky spectrum in the ESR looked pretty bad, so the measurement can not be restarted. 
The accelerator experts are currently looking into this problem.
  89   Wed Apr 2 18:22:30 2025 IDGeneralSpill cycle distribution
The spill cycle distributions is absolutely nuts since beginning of the shift. On the positive side: we got a lot of spills since FRS did not take many, so I think we got more than our parasitic 1:10 share...
  246   Sun Apr 6 20:49:25 2025 Ruijiu ChenAnalysisSpectrum during April 6 20:00- 20:19
  78   Wed Apr 2 12:13:57 2025 Michael, AlexAcceleratorSome empty injections triggered while beam patterns are changed
Operators seem to play with spill cycles, we get every 1:1 shot, then 1:10 again. During this, we noticed a few "empty injections" beeing triggered in the RSAs. They light up green, but spectrum is flat. Then it returns to normal operation again.