Mon Apr  7 18:58:04 2025, Shahab, DAQ, changed averaging in NPZ files 
 |  
new analysis settings for NPZ files:
 
 
[analysis]
 |  
   Mon Apr  7 18:52:15 2025, Shahab, Oliver, DAQ, updated DAQ settings 
 |  
changed 410 resonance frequency back to plunger 8
 
245 MHz plunger stays at 350
 
 |  
   Mon Apr  7 18:42:17 2025, Oliver, Filip, General, Lassie screenshots     
 |  
|   |  
   Mon Apr  7 18:37:41 2025, Shahab, Oliver, DAQ, updated DAQ settings 
 |  
changed 410 resonance frequency back to 212th harmonic
 
plunger 33
 
 |  
   Mon Apr  7 18:17:41 2025, Shahab, Oliver, DAQ, updated DAQ settings 
 |  
changed 410 resonance frequency back to 213th harmonic
 
plunger 20
 
 |  
   Mon Apr  7 17:51:15 2025, Shahab, General, HowTo change resonance frequency of 410 MHz Cavity     
 |  
step by step pictures:
 
 
sometimes the name of the motor connection is not available in the menu, it should be added manually.
 |  
   Mon Apr  7 17:26:57 2025, Shahab, Oliver, DAQ, New DAQ Settings   
 |  
new DAQ Settings for the RSAs:
 
 
414475588 (192Pb+82   at 214 harmonic)
 |  
   Mon Apr  7 17:25:00 2025, Oliver, Filip, General, Lassie screenshots     
 |  
|   |  
   Mon Apr  7 17:18:45 2025, Wolfram, Yuri, Sergey, General, Data from last 10 minutes are not useful (setting ESR) 
 |  
|   |  
   Mon Apr  7 17:07:33 2025, Team PLEIADES, Detectors, Moving OUTSIDE PLEIADES detector slowly in (and out) 
 |  
17:08 Tried to move outside particle detector (GE01DD2AG) in - it is stuck again :-(
 
17:18 Sergey tried to move it, now it moves again. Moved to -100 mm.
 
17:30 Moved detector to outside parking position |  
   Mon Apr  7 16:19:30 2025, Oliver, Filip, General, Lassie screenshots     
 |  
|   |  
   Mon Apr  7 16:11:44 2025, Ruijiu Chen, Yuri, Wolfram,, Analysis, PID of 192Pb+82 6x 
 |  
|   |  
   Mon Apr  7 16:07:42 2025, Shahab, General, all config files      
 |  
| here are all TOML config files of the automatic scripts. |  
   Mon Apr  7 15:47:03 2025, Shahab, Taka, Ruijiu, DAQ, change NAS and restart both acquisitions 
 |  
changed storage place to bank 1 of the NAS
 
restarted the NTCAP with new address
 
restarted Analyzers with new address
 |  
   Mon Apr  7 15:23:01 2025, Ragan, Wolfram, Sergey, Zsolt, Yuri, Rui-Jiu, General, ESR Setting change to 192Pb82+ 
 |  
| Today, until 11 am, data were taken for the 188Hf setting. Since then, we are now tuning on the 192Pb82+. |  
   Mon Apr  7 15:14:54 2025, Oliver, Filip, General, lassie screenshots     
 |  
|   |  
   Mon Apr  7 14:05:40 2025, Jelena, Guy, General, Lassie screenshots     
 |  
|   |  
   Mon Apr  7 13:18:27 2025, Jelena, Guy, General, Tuning     
 |  
| Beam was gone at 13:04 due to fragment tuning. |  
   Mon Apr  7 12:29:16 2025, Jelena, Guy, General, Lassie screenshots     
 |  
|   |  
   Mon Apr  7 11:35:23 2025, siddharth, Analysis, Sigma vs Mean Freq. Plot for 186Hf setting   
 |  
1st plot is of Sigma vs Freq for 186Hf72+ setting. The green vertical line is at 411.843MHz.
 
2nd plot is of Sigma vs Freq for 186Hf72+ setting from April 4th 20:00 to April 5th 09:00 with time cut 0.14, shift tracking applied and pwr limit 100, 
about 5200 injections.( the green vertical line is at 411.843 and not at 411.7)  |  
 
 |