Wed Apr 9 09:30:14 2025, Yuri, General, Slit changing
|
I would like to close E01 slits a bit more and get 30 min of data with higher
resolving power.
|
Thu Mar 27 09:42:04 2025, Ruijiu Chen, Simulations, Simulation Results for 194Pb and 188Hf 9x
|
Summary:
1.Simulated spectra for 194Pb and 188Hf.
|
Mon Apr 7 11:18:03 2025, Ruijiu Chen, Analysis, Simulation Results for 192Pb  
|
|
Tue Apr 8 12:08:56 2025, siddharth, Analysis, Sigma vs Mean Freq. Plot for 188Hf72+ setting 2 
|
This is sigma vs Freq plot for 188Hf72+ made out of 1hr of injections post Saturday, April 5th.
The 2nd photo Compares the resolution of 188Hf setting by looking at peaks of 205Au and 205Pb which are very close in frequency range. The resolution in
the second 188Hf72+ setting(on Right) seems much better as two peaks can be seen clearly. |
Fri Apr 4 17:30:25 2025, siddharth, Analysis, Sigma vs Mean Freq. Plot for 188Hf72+ setting
|
|
Mon Apr 7 11:26:52 2025, siddharth, Analysis, Sigma vs Mean Freq. Plot for 186Hf setting 
|
1st plot is of Sigma vs Freq for 186Hf72+ setting. The green vertical line is at 411.843MHz.
2nd plot is of Sigma vs Freq for 186Hf72+ setting from april 4th 20:00 to April 5th 09:00 with time cut 0.14, shift tracking applied and pwr-limit 100.
About 5200 Injections. |
Mon Apr 7 11:35:23 2025, siddharth, Analysis, Sigma vs Mean Freq. Plot for 186Hf setting 
|
1st plot is of Sigma vs Freq for 186Hf72+ setting. The green vertical line is at 411.843MHz.
2nd plot is of Sigma vs Freq for 186Hf72+ setting from April 4th 20:00 to April 5th 09:00 with time cut 0.14, shift tracking applied and pwr limit 100,
about 5200 injections.( the green vertical line is at 411.843 and not at 411.7) |
Thu Mar 27 17:20:40 2025, Esther, Yue, Carlo, Zac, Shahab, Detectors, Setup Genesys
|
We set up the Genesys. Channel map:
tr0:
|
Tue Apr 1 02:01:06 2025, Zac, Shahab, Ruijiu, Yuri, Sergey, Wolfram, Carlo, Michael, Accelerator, Settings lost
|
Settings lost after the beam was lost. Trying to recover particle identification now that beam has returned. |
Sat Apr 5 15:45:48 2025, Ruijiu, Ragan, Analysis, See single ion of 186Hf72+ and isomer in ntcap data  
|
The ntcap data record 410 detector continuously. The frame length is 26 ms/frame * 32 frames= 832 ms. |
Wed Apr 2 23:40:23 2025, JEL, ZN, General, Screenshots taken just as beam came back  
|
We are seeing spills being received but no peaks are seen in the analyzers.
|
Fri Apr 11 15:49:41 2025, Shahab, General, Screenshots of RSAs 11x
|
Screenshots of RSAs showing acquisition settings, for documentation, they show the time / date on the bottom left, in case needed for data analysis. |
Wed Apr 2 04:33:57 2025, Carlo, Zac, Chris, DAQ, Screenshots Lassie 
|
screenshots of Lassie |
Thu Apr 3 03:48:40 2025, JEL, ZN, Runs, Screenshots  
|
The peaks in the analyzer are slowly shifting back to the original position.
Note that a quadrupole was the cause of the issue 45 mins ago and it was cycled. Might be relevant... |
Thu Apr 3 06:16:32 2025, JEL, ZN, General, Screenshots  
|
Stable since last entry |
Thu Apr 3 06:56:31 2025, JEL, ZN, Runs, Screenshots  
|
|
Thu Apr 3 07:59:09 2025, ZP, CN, ID, General, Screenshots  
|
Screenshots before opening ESR. |
Thu Apr 3 10:07:34 2025, CN, ZP, CJG, MC, General, Screenshots  
|
|
Thu Apr 3 13:32:42 2025, CN, ID, General, Screenshots  
|
|
Thu Apr 3 16:44:18 2025, Usama, Kathrin, General, Screenshots   
|
|
|