HOME ESR EXPERIMENTS LABS etc
E121 E127 E132 E125 E143 laser_cooling_2021 E142 Ê128 E146 E0052 E0018 E0028 E0038 E0075 E0203_E0018
  masses & isomeres 2025, Page 6 of 17  Not logged in ELOG logo
Entry  Wed Apr 2 18:13:20 2025, ID, HA, General, RSA spectra IMG_0087.jpeg
 
Entry  Fri Mar 28 19:42:20 2025, Ruijiu Chen, Analysis, Queqiao Program for RSA Data 
The `queqiao` program used for RSA data analysis is located at:
  
  (pyroot) gpuuser@appc256:/data.local/G22-00018_00203/scripts/OnlineDataAnalysisSystem_rsa/queqiao

It is currently running in the screen session named:

  OnlineDataAnalysisSystem_rsa

1. Login the server gpuuser@appc256

2. Reattach to the session, use:

  screen -rd OnlineDataAnalysisSystem_rsa

3. Run the program manually, activate the pyroot environment and execute the following command:

  queqiao ../parameters/queqiaosettings_194Pb_rsa.toml

4. Then press "start" botton, the `queqiao` program copies data from:

  /mnt/ntcap-data2/G22-00018_00203/data/analyzers/RSA01
  /mnt/ntcap-data2/G22-00018_00203/data/analyzers/RSA02

to:

  /data.local/G22-00018_00203/data/analyzers/RSA01
  /data.local/G22-00018_00203/data/analyzers/RSA02
Entry  Thu Apr 3 02:01:29 2025, Zac, Johan, General, Quadrupole issues 
HKR has called someone to fix the quadrupole, they think it will take about an hour.
Entry  Mon Mar 24 14:42:33 2025, Jan Glorius, Collaboration, Proposals  G-22-00203-UR.pdfG-22-00018-1.pdf
Attached are the proposals submitted to and approved by G-PAC.
Entry  Thu Apr 3 01:56:57 2025, Zac, Johan, General, Problems with one of the quadrupoles 
Since around 01:45 we get spills but see nothing on analysers. HKR says there is a problem with one of the quadrupoles; they are working on it.
Entry  Fri Apr 4 20:48:25 2025, ID, General, Pocket moved 
20:48: Inside pocket moved to 60mm and back to the outside position.
Entry  Tue Apr 1 14:23:01 2025, JG, General, Pleiades pocket position tests 
We started playing with the detector pockets of the pleiades arrays at 14:23 01.04.2025.

This might disturb the beam sometimes.

The beam is lost in SIS at 14:35. 

Beam came back at 16:40, we continued playing with pleiades positions until 17:14.
Entry  Fri Mar 28 22:20:47 2025, Sergey, Shahab, General, Pattern pattern.JPG
the ACC pattern for both experiments.
Entry  Sat Apr 5 08:15:09 2025, Hannes, Cagla, General, Particles are back to previous intensity 2025-04-05_08-15-54-989.png2025-04-05_08-15-29-803.png
 
Entry  Thu Apr 3 15:21:42 2025, CJG, General, PLEIADES shift instructions 
PLEIADES shift instructions available at:
https://docs.google.com/document/d/19b4wyugC3OpVAjwt1ONM9u8EYdMJsBpL7GVNzoziv0M/edit?usp=sharing

Leakage current tracking:
https://docs.google.com/spreadsheets/d/1Gt1tFHwn4XFrJ5_-nQvTi635UD0aHgN6gCdXDTHQdkI/edit?gid=299353113#gid=299353113

Leakage currents should be documented every ~1-2 hours while the detectors are biased.
Entry  Tue Apr 1 23:23:18 2025, C Griffin, General, PLEIADES removed 
Leakage currents were steadily increasing in the PLEIADES detectors so we decided to stop taking data, move both the detectors back and turn off bias.
Entry  Sat Apr 5 12:22:12 2025, Team PLEIADES, Detectors, PLEIADES inside detector in 
12:23 moved PLEIADES inside detector in to 2mm.
Entry  Fri Apr 4 17:13:12 2025, Team Pleiades, Detectors, PLEIADES detector out 
17:12 We moved the PLEIADES detector out, both are outside now (in parking position)
Entry  Tue Apr 8 11:37:13 2025, Team PLEIADES, Detectors, PLEIADES 2025-04-08_11-38-37-375.png
11:37 Outside particle detector (GE01DD2AG) moved in to -100mm to take data
Entry  Tue Apr 8 20:50:59 2025, Ruijiu Chen, Analysis, PID of 204Pt77+ photo_2025-04-08_20-56-03.jpgsimulation_result_214.outsimulation_result_126.outNew_TEline2022-ESR-204Pt-H-208Pb-nostripper_512.4MeV.lppsummed_spectrum_time_cut.npz
 
Entry  Tue Apr 1 14:17:07 2025, Ruijiu, Analysis, PID of 194Pb82+ 2025.04.01.14.13.07 Screenshot_2025-04-01_14-16-42.png
datafile = "/data.local/G22-00018_00203/results/analyzers/RSA01/RSA01-2025.04.01.14.13.07.068.tiq_spectrum.npz"
filep = "/data.local/G22-00018_00203/scripts/OnlineDataAnalysisSystem/rionid_exercises/exercise_194Pb_Exp_2025/New_TEline2022-ESR-194Pb-208Pb-nostripper_524MeV.lpp"
alphap = "1.399"
harmonics = "211"
refion = "194Pb+82"
circumference = "108.34"
mode = "Frequency"
value = "408602000"
reload_data = true
nions = "100"
Entry  Mon Apr 7 16:11:44 2025, Ruijiu Chen, Yuri, Wolfram,, Analysis, PID of 192Pb+82 6x
 
Entry  Fri Apr 4 16:24:48 2025, Ruijiu, Yuri, Analysis, PID of 186Hf 7x
Code used to add up injection data.
(pyroot) gpuuser@appc256:/data.local/G22-00018_00203/scripts/OnlineDataAnalysisSystem/shift/20250331/data/2025.04.04.13.00$ find /data.local/G22-00018_00203/results/analyzers/RSA01 -name "RSA01-2025.04.04.*.tiq_spectrogram.npz" > filelist.txt
(pyroot) gpuuser@appc256:/data.local/G22-00018_00203/scripts/OnlineDataAnalysisSystem/shift/20250331/data/summed_spectrum$ python npz_addup.py --time-cut 0.14 filelist.txt
Entry  Mon Mar 31 22:13:04 2025, Shahab, Yue, Carlo, Zac, Esther, Runs, PID continued photo_2025-03-31_22-17-30.jpg
continuing PID with better / higher resolution:

RSA01-2025.03.31.21.10.54.758.tiq_spectrum.npz
...
RSA01-2025.03.31.21.12.29.106.tiq_spectrum.npz

trying to do PID....
Entry  Mon Mar 31 22:03:56 2025, Shahab, Yue, Carlo, Zac, Esther, Runs, PID 
trying to do PID with some injections:

RSAs are still on winter time. they show summer time but files have winter time.

data used for PID is range from:

RSA01-2025.03.31.20.21.13.217.tiq_spectrum.npz
...
RSA01-2025.03.31.20.53.06.492.tiq_spectrum.npz

gamma_t = 1.4

but files are not so good.
ELOG V3.1.5-fc6679b