Tue Apr 1 23:56:18 2025, Shahab, Carlo, Zac, Yue, Michael, DAQ, Change of RSA01 settings for new harmonic=212.
|
23:55 stop the RSAs.
410:
|
Mon Mar 31 20:53:02 2025, Shahab, Carlo, Zac, Esther, Michael, DAQ, DAQ start
|
20:28 started NTCAP
started queqiao file transfer for RSAs only
started analyzer looper for RSAs
|
Mon Mar 31 16:53:03 2025, Shahab, DAQ, stop and delete NTCAP data from Weekend test
|
stop and delete NTCAP data from Weekend test
for now the NAS data2 bank has been flushed to make sure good operation for today's beam.
|
Tue Apr 1 23:07:15 2025, Shahab, DAQ, short interruption of queqiao script for RSAs
|
has been restored. |
Wed Apr 2 20:57:34 2025, Shahab, Detectors, 10GB cables for the DAQ rack
|
We have been working together with IT on the speed of data transfer: with the new 10 GB interface we can now transfer data from NAS to Lustre with 400MB/s.
From NAS to GPU Computer up to 700MB/s. All cables around the rack are now 10GB capable. |
Fri Apr 4 01:12:03 2025, Shahab, Analysis, NPZ add up script 
|
Since there are many NPZ summer scripts around, I thought I would also share mine. This one takes advantage of the power of filelists and has a progress
bar. Creating file lists gives you more control over the range of analyzed data, for example, the command:
|
Sat Apr 5 15:25:16 2025, Shahab, DAQ, stop RSA02 looper script
|
2025-04-05 15:25
Stop the RSA02 looper script to change the settings of analysis |
Sat Apr 5 20:58:37 2025, Shahab, DAQ, removed temporary NPZ files for additional disk space
|
Deleted 14 TB of unused spectrum.npz files from APPC, so that there is more disk space.
switched off the production of .tiq_spectrum.npz files to save disk space in the looper script
|
Mon Apr 7 16:07:42 2025, Shahab, General, all config files    
|
here are all TOML config files of the automatic scripts. |
Mon Apr 7 17:51:15 2025, Shahab, General, HowTo change resonance frequency of 410 MHz Cavity   
|
step by step pictures:
sometimes the name of the motor connection is not available in the menu, it should be added manually.
|
Mon Apr 7 18:58:04 2025, Shahab, DAQ, changed averaging in NPZ files
|
new analysis settings for NPZ files:
[analysis]
|
Fri Apr 11 15:49:41 2025, Shahab, General, Screenshots of RSAs 11x
|
Screenshots of RSAs showing acquisition settings, for documentation, they show the time / date on the bottom left, in case needed for data analysis. |
Fri Apr 11 15:57:37 2025, Shahab, General, More screenshots of RSAs 11x
|
more screen shots of RSAs. |
Wed Apr 9 00:08:30 2025, Sergey, Yuri and Xinliang, General, Move of the scraper positions at ESR
|
From roughly … to 0:05AM, Sergey moved GEEXDS1HA (not
changed
in the end) and GE01DS3HG (changed from -85 to -80 mm) to reduce
|
Fri Mar 28 22:20:47 2025, Sergey, Shahab, General, Pattern
|
the ACC pattern for both experiments. |
Tue Apr 8 23:08:15 2025, Sergey Litvinov, Xinliang Yan, General, Tuning of the ion optics
|
From roughly 10:45 pm to 11:05 pm, Sergey tuned the
ion optics of the ESR to see if the mass resolution at
413.55735 MHz improves or not. Please note that the
|
Wed Apr 2 10:02:40 2025, Sergey + Yuri, Accelerator, ESR Timeout
|
At around 9:40, ESR timeout changed from 10 s to 30 s
Triggering only on real injections.
Before that, every second injection was not real but the old one. They can be identified since they should have no "kicker" disturbance. |
Wed Apr 2 16:28:14 2025, SS, ID, HA etc, DAQ, NTCAP stop/start
|
NTCAP was stopped and restarted. |
Thu Apr 3 13:36:17 2025, Ruijiu,Yuri, Wolfram,Zsolt, Analysis, 188Hf identification    
|
|
Fri Apr 4 16:24:48 2025, Ruijiu, Yuri, Analysis, PID of 186Hf 7x
|
Code used to add up injection data.
(pyroot) gpuuser@appc256:/data.local/G22-00018_00203/scripts/OnlineDataAnalysisSystem/shift/20250331/data/2025.04.04.13.00$ find /data.local/G22-00018_00203/results/analyzers/RSA01
-name "RSA01-2025.04.04.*.tiq_spectrogram.npz" > filelist.txt
|