ID |
Date |
Author |
Category |
Subject |
Text |
 |
206
|
Sat Apr 5 17:26:48 2025 |
Team PLEIADES | Detectors | Outside pocket "repair" | We tried to convince the outside pocket to
move, no success. We can hear the "hissing
sound" of the pressurized air but no movement. |
|
212
|
Sat Apr 5 19:20:32 2025 |
Team PLEIADES | Detectors | Outside detector moved out again | 19:20 The outside and inside PLEIADES detectors
are both moved back into their parking positions.
Shifts should continue monitoring the leakage |
|
311
|
Tue Apr 8 11:57:56 2025 |
Team PLEIADES | Detectors | Outside detector moved out | 12:00 Outside particle detector moved out
to parking position again (-125 mm) |
|
52
|
Tue Apr 1 22:03:07 2025 |
Jeroen, Zac, Esther, Shahab, Wolfram | DAQ | Optimisation of settings | Estimation of potential gain by changing.
Files from this points are going to rubbish.
Potential gains are c. 20%
|
|
96
|
Wed Apr 2 23:15:52 2025 |
Zac, Johan | Accelerator | No injections from SIS | Night shift starts with no injections from
SIS! We still have triggers; we called HKR
and are waiting for response. |
|
74
|
Wed Apr 2 10:05:06 2025 |
Michael, Alex, Yuri | Accelerator | No beam since 09:59 | The SIS kicker has failed again. |
|
76
|
Wed Apr 2 10:55:16 2025 |
Michael, Alex, Wolfram | Accelerator | No beam in the ESR | Since few minutes do not see any beam in the
ESR (on RSAs). There is beam in SIS and injection
requests from the ESR seem to be there as |
|
80
|
Wed Apr 2 13:27:52 2025 |
Michael, Alex, Maeve | Accelerator | No beam in the ESR | There is no beam in the ESR since couple of
minutes. According to the info from HKR,
the experts started to repair the magnets |
|
70
|
Wed Apr 2 08:04:47 2025 |
Michael, Alex | General | No beam | The SIS kicker has failed again at 08:01.
Since this has happened already few times,
the experts from the on-call duty service |
|
41
|
Tue Apr 1 14:54:24 2025 |
all | General | No SIS beam since 14:35 | |
|
44
|
Tue Apr 1 16:44:32 2025 |
Jeroen, Esther | General | No SIS beam since 14:35 | Beam resumed at 16:40. |
 |
209
|
Sat Apr 5 17:57:08 2025 |
Ragan, Dima, Zac, Shahab | Calibration | New Settings Resonators | New settings for resonators:
410: plunger stay the same
|
|
284
|
Mon Apr 7 17:26:57 2025 |
Shahab, Oliver | DAQ | New DAQ Settings | new DAQ Settings for the RSAs:
414475588 (192Pb+82 at 214 harmonic)
|
 |
84
|
Wed Apr 2 16:28:14 2025 |
SS, ID, HA etc | DAQ | NTCAP stop/start | NTCAP was stopped and restarted. |
|
10
|
Mon Mar 31 17:46:21 2025 |
Esther | DAQ | NTCAP scaler assignment | The setup contains two NI-6612 I/O cards with
BNC-2121 connector accessories that provide
eight inputs each for TTL scaler signals. |
|
237
|
Sun Apr 6 16:24:36 2025 |
Wolfram, Shahab, Moriguchi, Taka | DAQ | NTCAP restart | NTCAP restarted with new timestamp. |
|
329
|
Wed Apr 9 11:18:27 2025 |
Esther | DAQ | NTCAP off, RSA triggers disconnected | The NTCAP computer and crate are switched
off.
The triggers are disconnected from the RSAs, |
|
42
|
Tue Apr 1 15:32:59 2025 |
Zac | DAQ | NTCAP Restarted | NTCAP Has been restarted (we restart every
day around 15:00 so data goes in a new folder) |
|
137
|
Fri Apr 4 01:12:03 2025 |
Shahab | Analysis | NPZ add up script | Since there are many NPZ summer scripts around,
I thought I would also share mine. This one
takes advantage of the power of filelists |
 |
306
|
Tue Apr 8 09:53:04 2025 |
Team PLEIADES | Detectors | Moving outside particle detector in for 20min | 9:53 Data taking with outside detector (GE01DD2AG)
moved in to -110mm |
|