117
|
Thu Apr 3 09:53:02 2025 |
Ruijiu Chen,Wolfram | Analysis | Good injection ratio | Currently, we only use 37% of the injections
in our data analysis. However, 63% of the
injections have a height below 100, and these |
|
69
|
Wed Apr 2 07:41:10 2025 |
Michael, Alex | General | Frequency shift in Schottky | After the beam was restored at 07:25, we
think that the frequency peak in the 244
MHz RSA2 has jumped again (closer to the |
|
115
|
Thu Apr 3 09:34:42 2025 |
ID | General | Finished in the ESR as of 9:05 | We had stopped the RSAs at 8:00 (call for
restart)
Time stamp computer stopped and started at |
|
90
|
Wed Apr 2 18:31:52 2025 |
ID | General | FYI for morning shifts Thu | The PLEIADES team (pocket detectors) has discussed
with Wolfram to get access to the ESR tomorrow
(Thu) morning ~8:00 to check their detectors |
|
114
|
Thu Apr 3 08:02:04 2025 |
Team PLEIADES (JG, ID, CJG, MC) | Detectors | Entering ESR for PLEIADES | We are going to enter the ESR to check on
the PLEIADES pocket detectors and install
a nitrogen cooling. |
|
72
|
Wed Apr 2 09:28:59 2025 |
Michael, Alex | General | Empty injections in the ESR | Since the FRS started to take the beam again,
the ESR gets 1/10 shots from SIS. But, the
ESR seems to request about twice more frequently |
|
147
|
Fri Apr 4 09:45:02 2025 |
Ragan, Wolfram, Sergey | General | Electron Cooler | Regina, Jan, and Markus are in the ESR to
check the electron cooler. |
|
149
|
Fri Apr 4 11:00:35 2025 |
Ragan, Wolfram, Sergey, Zsolt | General | Electron Cooler | Electron cooler anode voltage needs a repair
which might take 20-30 mins. If it takes
longer, we'll proceed without a cooler curve |
|
150
|
Fri Apr 4 11:15:05 2025 |
Ragan, Wolfram, Sergey, Zsolt | General | Electron Cooler | No additional HV. So, have to proceed without
the cooler.
Spare Power supply did not work either, we |
|
148
|
Fri Apr 4 10:36:40 2025 |
Ragan, Wolfram, Sergey, Zsolt | General | ESR setting change from 188Hf72+ to 186Hf72+ | ESR setting is changed from 188Hf72+ to 186Hf72+.
SIS-18 beam energy for the primary beam transmission
check is 528 MeV/u. |
|
161
|
Fri Apr 4 17:10:35 2025 |
H. Weick, S. Litvinov | Accelerator | ESR scraper setting | the new scraper setting for good isochronicity
but still acceptable intensity losses is:
Done at ~ 15:00 today.
|
|
65
|
Wed Apr 2 07:16:33 2025 |
Carlo, Chris, Alex, Michael | DAQ | ESR not requesting | 7:05 ESR not requesting new pulses from the
SIS.
Operators are trying to fix the problem.
|
|
73
|
Wed Apr 2 10:02:40 2025 |
Sergey + Yuri | Accelerator | ESR Timeout | At around 9:40, ESR timeout changed from 10
s to 30 s
Triggering only on real injections.
|
|
124
|
Thu Apr 3 15:57:16 2025 |
Shahab, Yue, Zac, Esther | DAQ | Data acquisitions running | All data acquisitions (both RSAs and NTCAP)
are now running. |
|
12
|
Mon Mar 31 20:53:02 2025 |
Shahab, Carlo, Zac, Esther, Michael | DAQ | DAQ start | 20:28 started NTCAP
started queqiao file transfer for RSAs only
started analyzer looper for RSAs
|
|
50
|
Tue Apr 1 20:37:04 2025 |
Jeroen | DAQ | Change of settings for shorter acq. window | Acquisition stopped at 20:36.
First file from this setting: RSA01-2025.04.01.03.52.59.247.tiq
|
|
51
|
Tue Apr 1 21:05:20 2025 |
Jeroen, Zac, Esther, Shahab, Wolfram | DAQ | Change of settings for shorter acq. window | > Acquisition stopped at 20:36.
>
> First file from this setting: RSA01-2025.04.01.03.52.59.247.tiq
|
|
57
|
Tue Apr 1 23:56:18 2025 |
Shahab, Carlo, Zac, Yue, Michael | DAQ | Change of RSA01 settings for new harmonic=212. | 23:55 stop the RSAs.
410:
|
|
64
|
Wed Apr 2 05:48:31 2025 |
Chris, Carlo, Zac | General | Beam returned | Beam was returned to the ESR at 05:11.
HKR said there had been some problem with |
|
111
|
Thu Apr 3 06:33:08 2025 |
Zac, Johan | General | Beam lost at 06:27, returned at 06:34 | Spike in beam intensity at 06:27 (5x usual
intensity) and then beam is lost. HKR says
it's a problem with the magnet's power supply. |
|