HOME ESR EXPERIMENTS LABS etc
E121 E127 E132 E125 E143 laser_cooling_2021 E142 Ê128 E146 E0052 E0018 E0028 E0038
  Bound beta decay experiment on Tl-205  Not logged in ELOG logo
Message ID: 110     Entry time: Tue Mar 31 23:31:41 2020
Author: Shahab 
Category: Runs 
Subject: alpha_p calibration 
Vc = 212849.9349
Ic = 0.2

1)

Vcc=6400
f= 245.314
Veff= 219218.2989884789
β= 0.7143483279777152 
γ= 1.4289995125817443  


2)

Vcc=6800
f=245.227
Veff= 219618.31558866
β= 0.7147234572628363 
γ= 1.4297823255462372  

3)

Vcc=6000
f=245.404
Veff= 218818.2823347592
β= 0.7139723840585469 
γ= 1.4282166995124788  


Taking 1) and 2):

η : 0.33044950273377705 

αp1: 0.15925696358166558 
αp2: 0.1587208769044816 

Taking 1) and 3):

η : 0.34166460537796267 

αp1: 0.14804186093747995 
αp2: 0.14857882942379202 

Taking 2) and 3):

η : 0.33653854822327256 

αp1: 0.1526318314149861 
αp2: 0.15370488657848214  


αp average: 0.1534892081401479
Attachment 1: ap_calibration.jpg  93 kB  Uploaded Wed Apr 1 00:31:51 2020  | Show | Show all