ID |
Date |
Author |
Category |
Subject |
98
|
Mon Mar 30 14:24:46 2020 |
ruijiu | DAQ | stop taking data. |
1. stop run0272.lmd.
2. stop NTCAP.
NTCAp file:
SC_2020-03-30_09-28-14
IQ_2020-03-30_09-28-14
(saved in drive: p) |
101
|
Mon Mar 30 16:25:05 2020 |
ruijiu | Detectors | turn down the HV |
turn down the hv and pull out the detector.
suggest by
Hi everybody,
is there now much more rate on the detectors?
Perhaps it helps to turn down the bias for a while and to take the detectors out of the beam, by pulling the pocket out?
And then see if the leakage current comes down again.
good luck, Thomas
***********************************************
Dr. Thomas Faestermann | Tel: +49-89-2723868
Physik Department E12 |
Techn. Univ. Muenchen | Mob: +49-1626193388 |
102
|
Mon Mar 30 16:37:53 2020 |
ruijiu | Analysis | |
|
106
|
Tue Mar 31 15:30:43 2020 |
ruijiu | Analysis | The beam position on DSSD with different conditions on on the dEE spectrum |
I analyzed the first measurement with 206Pb81+ beam, run 250-267. |
Attachment 1: 202003311453.png
|
|
Attachment 2: 202003311508.png
|
|
Attachment 3: 202003311509.png
|
|
Attachment 4: 202003311510.png
|
|
Attachment 5: 202003311511.png
|
|
Attachment 6: 202003311512.png
|
|
111
|
Wed Apr 1 01:02:24 2020 |
ruijiu | Detectors | the detector cable is disconnected. |
|
112
|
Wed Apr 1 01:05:36 2020 |
ruijiu | Detectors | detector position fixed at 60 mm |
The detector cable was disconnected . We entered and reconnected the cable. |
Attachment 1: VID_20200401_010416.mp4
|
120
|
Thu Apr 2 12:52:25 2020 |
ruijiu | General | setup FRS with 2 g/cm2 degrader. |
Yuri sets up FRS with 2 g/cm2 degrader (previous one is 1 g/cm2). The ESR is not changed. The contamination should be less now. |
171
|
Thu Apr 9 11:47:28 2020 |
ruijiu | | backup data |
2020.4.8 12:00Started copying
data。
2020.4.9 11:52 Copied 6.3TB
data. The copy speed is 65-67MB/s.
2020.4.15 Bring the two USB hard disk to my office and connect them to lxg1298 computer.
Send email |
Attachment 1: IMG_20200409_113155.jpg
|
|
172
|
Fri Apr 17 18:27:34 2020 |
ruijiu | Analysis | backup data |
1.connect USB harddisk to computer lxg1254 and copy data to sever.
sync -rtmv --progress --checkSUD /media/sdgl/data/ litv-exp@sbk0l9:/lustre/ap/litv-exp/2020-
04-14 e121_rchen/NTCAP/hd1
2020.05.02 08:06 copied 11.88 TB to server. 1.8TB rest on hard disk. |
Attachment 1: IMG_20200417_162202.jpg
|
|
167
|
Mon Apr 6 14:17:54 2020 |
Yuri, Shahab | Runs | FRS valves |
We saw reduction in ESR beam life. It turned out that FRS has opened valves and venting caused us reduction of the quality of vacuum in ESR leading to beam loss. We manged to closed GEE5VV so that now beam is stable somehow.
how could you guys!!!!
arrrrgggggggg!!!!!!! |
Attachment 1: 2020-04-06_14-22-20-965.png
|
|
105
|
Tue Mar 31 00:47:18 2020 |
Yuri | Runs | S2 slits 0/+35 mm, target bump +13 mm |
Run start: 0276.lmd |
81
|
Mon Mar 30 07:34:06 2020 |
Tino | Runs | Second measurement with 206Pb81+ beam at I_cooler = 20 mA |
I_cooler = 20 mA
beam: 206Pb81+
energy: 400 MeV/u
purpose: data for the measurement of half life of 206Pb81+ due to its interaction with electron cooler and residual gas
Detector position (CsISiPHOS): 60 mm
Detector position (MWPC): -10 mm
run start at 06:08 , run file: run0270.lmd (0268.lmd and 0269.lmd are garbage files)
file running: 0270.lmd
_______________________________________________________________________________
time: 07:30
I_cooler = -01 mA
ESR particles: 2.8E5
NTCAp file:
SC_2020-03-30_06-11-08
IQ_2020-03-30_06-11-16
(saved in drive: p)
copy and repeat the above (below the line) every 30 minutes |
82
|
Mon Mar 30 08:00:40 2020 |
Tino | Runs | Second measurement with 206Pb81+ beam at I_cooler = 20 mA |
I_cooler = 20 mA
beam: 206Pb81+
energy: 400 MeV/u
purpose: data for the measurement of half life of 206Pb81+ due to its interaction with electron cooler and residual gas
Detector position (CsISiPHOS): 60 mm
Detector position (MWPC): -10 mm
run start at 06:08 , run file: run0270.lmd (0268.lmd and 0269.lmd are garbage files)
file running: 0270.lmd
_______________________________________________________________________________
time: 08:00
I_cooler = -01 mA
ESR particles: 2.6E5
NTCAp file:
SC_2020-03-30_06-11-08
IQ_2020-03-30_06-11-16
(saved in drive: p)
copy and repeat the above (below the line) every 30 minutes |
83
|
Mon Mar 30 08:32:05 2020 |
Tino | Runs | Second measurement with 206Pb81+ beam at I_cooler = 20 mA |
I_cooler = 20 mA
beam: 206Pb81+
energy: 400 MeV/u
purpose: data for the measurement of half life of 206Pb81+ due to its interaction with electron cooler and residual gas
Detector position (CsISiPHOS): 60 mm
Detector position (MWPC): -10 mm
run start at 06:08 , run file: run0270.lmd (0268.lmd and 0269.lmd are garbage files)
file running: 0270.lmd
_______________________________________________________________________________
time: 08:30
I_cooler = -01 mA
ESR particles: 2.5E5
NTCAp file:
SC_2020-03-30_06-11-08
IQ_2020-03-30_06-11-16
(saved in drive: p)
copy and repeat the above (below the line) every 30 minutes |
84
|
Mon Mar 30 08:56:04 2020 |
Tino | Runs | Second measurement with 206Pb81+ beam at I_cooler = 10 mA |
I_cooler = 10 mA
beam: 206Pb81+
energy: 400 MeV/u
purpose: data for the measurement of half life of 206Pb81+ due to its interaction with electron cooler and residual gas
Detector position (CsISiPHOS): 60 mm
Detector position (MWPC): -10 mm
run start at 08:52 , run file: run0271.lmd
_______________________________________________________________________________
time: 08:52
I_cooler = -01 mA
SIS particles: 3.4E8
ESR particles: 4.7E6
NTCAp file:
SC_2020-03-30_08-54-42
IQ_2020-03-30_08-54-42
(saved in drive: p)
copy and repeat the above (below the line) every 30 minutes |
85
|
Mon Mar 30 09:26:37 2020 |
Tino | Runs | Stopped Second measurement with 206Pb81+ beam at I_cooler = 10 mA |
Stopped Data recording for Restart of the measurement
I_cooler = 10 mA
beam: 206Pb81+
energy: 400 MeV/u
purpose: data for the measurement of half life of 206Pb81+ due to its interaction with electron cooler and residual gas
Detector position (CsISiPHOS): 60 mm
Detector position (MWPC): -10 mm
run start at 08:52 , run file: run0271.lmd
_______________________________________________________________________________
time: 09:27
I_cooler = -01 mA
SIS particles: 3.4E8
ESR particles: 2.5E5
NTCAp file:
SC_2020-03-30_08-54-42
IQ_2020-03-30_08-54-42
(saved in drive: p)
copy and repeat the above (below the line) every 30 minutes |
86
|
Mon Mar 30 09:34:02 2020 |
Tino | Runs | Restart of second measurement with 206Pb81+ beam at I_cooler = 10 mA |
Stopped Data recording for Restart of the measurement
I_cooler = 10 mA
beam: 206Pb81+
energy: 400 MeV/u
purpose: data for the measurement of half life of 206Pb81+ due to its interaction with electron cooler and residual gas
Detector position (CsISiPHOS): 60 mm
Detector position (MWPC): -10 mm
run start at 09:28 , run file: run0272.lmd
_______________________________________________________________________________
time: 09:28
I_cooler = -01 mA
SIS particles: 3.1E8
ESR particles: 5.7E6
NTCAp file:
SC_2020-03-30_09-28-14
IQ_2020-03-30_09-28-14
(saved in drive: p)
copy and repeat the above (below the line) every 30 minutes |
87
|
Mon Mar 30 10:01:31 2020 |
Tino | Runs | Second measurement with 206Pb81+ beam at I_cooler = 10 mA |
I_cooler = 10 mA
beam: 206Pb81+
energy: 400 MeV/u
purpose: data for the measurement of half life of 206Pb81+ due to its interaction with electron cooler and residual gas
Detector position (CsISiPHOS): 60 mm
Detector position (MWPC): -10 mm
run start at 09:28 , run file: run0272.lmd
_______________________________________________________________________________
time: 10:00
I_cooler = -01 mA
ESR particles: 2.8E5
NTCAp file:
SC_2020-03-30_09-28-14
IQ_2020-03-30_09-28-14
(saved in drive: p)
copy and repeat the above (below the line) every 30 minutes |
88
|
Mon Mar 30 10:32:01 2020 |
Tino | Runs | Second measurement with 206Pb81+ beam at I_cooler = 10 mA |
I_cooler = 10 mA
beam: 206Pb81+
energy: 400 MeV/u
purpose: data for the measurement of half life of 206Pb81+ due to its interaction with electron cooler and residual gas
Detector position (CsISiPHOS): 60 mm
Detector position (MWPC): -10 mm
run start at 09:28 , run file: run0272.lmd
_______________________________________________________________________________
time: 10:31
I_cooler = -01 mA
SIS particles: 3.1E8
ESR particles: 2.7E5
NTCAp file:
SC_2020-03-30_09-28-14
IQ_2020-03-30_09-28-14
(saved in drive: p)
copy and repeat the above (below the line) every 30 minutes |
89
|
Mon Mar 30 10:57:43 2020 |
Tino | Runs | Second measurement with 206Pb81+ beam at I_cooler = 10 mA |
I_cooler = 10 mA
beam: 206Pb81+
energy: 400 MeV/u
purpose: data for the measurement of half life of 206Pb81+ due to its interaction with electron cooler and residual gas
Detector position (CsISiPHOS): 60 mm
Detector position (MWPC): -10 mm
run start at 09:28 , run file: run0272.lmd
_______________________________________________________________________________
time: 10:57
I_cooler = -01 mA
SIS particles: 3.1E8
ESR particles: 2.7E5
NTCAp file:
SC_2020-03-30_09-28-14
IQ_2020-03-30_09-28-14
(saved in drive: p)
copy and repeat the above (below the line) every 30 minutes |