HOME ESR EXPERIMENTS LABS etc
E121 E127 E132 E125 E143 laser_cooling_2021 E142 Ê128 E146 E0052 E0018
  proton-capture on 118Te  Not logged in ELOG logo
Message ID: 112     Entry time: Sat Mar 21 09:00:29 2020
Author: Ragan, RuiJiu 
Category: Runs 
Subject: run entry - run057 
Year:  
beam: 118Te52+
energy: 10 MeV/u

purpose: data with TARGET ON

Detector position (Si): -24 mm

run start at 08:30 , first file: run057_0001.lmd
run stop  at xx:xx , last file:  run0xx_0xxx.lmd

_______________________________________________________________________________

time: 9:00 am.

ON Rates
Si_X:      0 Hz
Si_Y:      0 Hz
Xray_35:   0 Hz
Xray_90:   46 Hz
Xray_145:  35 Hz
BaF_OR:    15Hz

Si voltage:          60.02 V  
Si leakage current:  4.03 uA


SIS particles before:           3.4e9
ESR particles at injection:     estimated ~1.3e6
ESR particles after decel.:     
Target ON density:              1.5e13


copy and repeat the above (below the line) every 30 minutes
ELOG V3.1.5-fc6679b