HOME ESR EXPERIMENTS LABS etc
E121 E127 E132 E125 E143 laser_cooling_2021 E142 Ê128 E146 E0052 E0018 E0028 E0038
  proton-capture on 118Te  Not logged in ELOG logo
Message ID: 153     Entry time: Sat Mar 21 23:19:14 2020
Author: Jan 
Category: Analysis 
Subject: 118Te52+ on H2-target - Xray spectrum 90 degree 
Year:  
The attached spectrum is for the 90 degree X-ray detector taken for about 3 hours with 118Te52+.
We see two peaks at ~29 keV (K-alpha) and 44 keV (K-REC).

The resolution is about 1.5 keV, and the signal-to-background ratio is also really bad.

The increase of background events at higher E might be induced by Compton scattering of a high E gamma ray from the BaF detectors, which are active and sit close by (not anymore).
Attachment 1: 90_deg_118Te_runs64to66.png  9 kB  | Show | Show all
ELOG V3.1.5-fc6679b