HOME
ESR
EXPERIMENTS
LABS etc
|
E121
E127
E132
E125
E143
laser_cooling_2021
E142
Ê128
E146
E0052
E0018
E0028
E0038
|
proton-capture on 118Te |
Not logged in |
|
|
Message ID: 365
Entry time: Fri May 21 14:06:23 2021
|
Author: |
Jan |
Category: |
Runs |
Subject: |
Run 0054 |
Year: |
2021 |
|
|
open file : e127b_run0054.lmd
beam: 124Xe54+
energy: 7 MeV/u
cooler voltage:
purpose:
Illumination of the detector to see if the gain settings are ok.
Spectra look reasonable, rates are low.
Detector position (Si): -25 mm
GE01DD1IG position (Scraper): out/not used
run start: 14:06:04 21-05-2021
run stop: 15:14:48 21-05-2021
_______________________________________________________________________________
ON Rates
Si_bdt: 31 Hz
Xray_35: 145 Hz
Xray_90: 10 Hz
Xray_145: 56 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 350 uA
SIS particles before:
ESR current at injection: 3e7
ESR particles after decel.: 5e6
Target ON density: 9e13 |