HOME
ESR
EXPERIMENTS
LABS etc
|
E121
E127
E132
E125
E143
laser_cooling_2021
E142
Ê128
E146
E0052
E0018
E0028
E0038
|
proton-capture on 118Te |
Not logged in |
|
|
Message ID: 375
Entry time: Sat May 22 02:48:44 2021
|
Author: |
Cobus, Michele |
Category: |
Runs |
Subject: |
Run 0062 |
Year: |
2021 |
|
|
open file : e127b_run0062.lmd
beam: 124Xe54+
energy: 7 MeV/u
cooler voltage:
purpose:
Reference measurement
Detector position (Si): -25 mm
GE01DD1IG position (Scraper): out/not used
run start: 02:41: 22-05-2021
run stop: 02:48:21 22-05-2021
_______________________________________________________________________________
ON Rates
Si_ON_bdt: 30 Hz
Xray_ON_bdt: 300 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 340 uA
SIS particles before: 3.0e7
ESR current at injection: 1.07e7
ESR particles after decel.:
Target ON density: 9.8e13
Comment: Running with low intensity beam (factor of 4 below normal).
Operator working on problem. |