HOME ESR EXPERIMENTS LABS etc
E121 E127 E132 E125 E143 laser_cooling_2021 E142 Ê128 E146 E0052 E0018
  proton-capture on 118Te  Not logged in ELOG logo
Message ID: 73     Entry time: Fri Mar 20 05:03:03 2020
Author: Shahab 
Category: Runs 
Subject: run entry - run046 
Year:  
beam: 124Xe54+
energy: 10 MeV/u

purpose: data with TARGET ON

Detector position (Si): -25 mm

run start at 04:31 , first file: run046_0001.lmd
run stop  at xx:xx , last file:  run0xx_0xxx.lmd

_______________________________________________________________________________

time: 05:00

ON Rates
Si_X:       1 Hz
Si_Y:       1 Hz
Xray_35:   3 Hz
Xray_90:   28 Hz
Xray_145:   24 Hz
BaF_OR:    2452 Hz

Si voltage:          60.02 V  
Si leakage current:  3.93 uA


SIS particles before:           2e9
ESR particles at injection:     5e7
ESR particles after decel.:     2e6
Target ON density:              1.8e13


copy and repeat the above (below the line) every 30 minutes