HOME
ESR
EXPERIMENTS
LABS etc
|
E121
E127
E132
E125
E143
laser_cooling_2021
E142
Ê128
E146
E0052
E0018
E0028
E0038
|
proton-capture on 118Te |
Not logged in |
|
|
Message ID: 83
Entry time: Fri Mar 20 13:21:33 2020
|
Author: |
Jan, Laszlo |
Category: |
Analysis |
Subject: |
124Xe data of first night |
Year: |
|
|
|
The unpacked data of all runs from the first night (46-50) is located at
litv-exp@lxg0188:/data.local2/E127_lmd/124Xe_1st_night.root
By taking a very quick look at the Silicon xy position histo, one can identify (please not the number of counts) clusters of hits. The x=0 and x=1 strips sees the forward scattering Rutherford particles, which remained even after scraping at 3.5cm away from the beam. This idea is supported by the simulations. Backscattered Rutherford components cannot be identified simply because of their low count rate (the exact rate should be double check). The second cluster in the middle of the detector must be our pg peak. For x>=7 strip we see the pn channel. It overlaps with the pg peak both in the position and in the energy. The energy vs Xstrip histo is NOT gainmatched, yet. Hard to make statements, but so far it seem to support the conclusions based on the position histo. The energies seem to corrsepond to the simulation: forward Rutherford, pg at same level; pn is a bit below ( ~.8% energy separation of the centers). The separation in the enregy for the backscattered Rutherford should be in the range of 2%. |
|
|
|
|
|
|
|