ID |
Date |
Author |
Category |
Subject |
Year |
Text |
 |
154
|
Sat Mar 21 23:24:09 2020 |
Dima, Pierre | Runs | run entry - run068 | | open file : run068
beam: 118Te52+
|
|
153
|
Sat Mar 21 23:19:14 2020 |
Jan | Analysis | 118Te52+ on H2-target - Xray spectrum 90 degree | | The attached spectrum is for the 90 degree
X-ray detector taken for about 3 hours with
118Te52+.
|
|
152
|
Sat Mar 21 23:12:38 2020 |
Jan | Detectors | removed BaF detectors | | After run 67 and before run 68, the BaF detectors
have been removed in order to reduce the
Compton background in the x-ray detectors. |
|
151
|
Sat Mar 21 23:07:00 2020 |
Laszlo | General | 1672. MCP file was (recoils) was not closed | | 1672. MCP file was (recoils) was not closed
when we refilled the Xrays and did the cable
change of 90 and 145 xrays
|
|
150
|
Sat Mar 21 22:59:09 2020 |
Sergiy,Ruijiu | Runs | run entry - run068 | | open file : run068
beam: 118Te52+
|
|
149
|
Sat Mar 21 22:57:28 2020 |
Laszlo, Jan | DAQ | changing cables of the Xray 90 and 145 | | Energy signals of 90 and 145 degree detector
have been checked and exchanged
They were connected to the wrong ADC channel.
|
|
148
|
Sat Mar 21 21:41:29 2020 |
Sergiy,Ruijiu | Runs | run entry - run067 | | open file : run067
beam: 118Te52+
|
|
147
|
Sat Mar 21 21:36:06 2020 |
Jan | Runs | target incident | | in run 66 or 67 we had a single ESR cycle
for which the target didn't switch off for
new injection and deceleration etc.
|
|
146
|
Sat Mar 21 21:11:46 2020 |
Sergiy,Ruijiu | Runs | run entry - run067 | | open file : run067
beam: 118Te52+
|
|
145
|
Sat Mar 21 20:39:38 2020 |
Sergiy,Ruijiu | Runs | run entry - run067 | | open file : run067
beam: 118Te52+
|
|
144
|
Sat Mar 21 20:11:59 2020 |
Sergiy | Runs | run entry - run066 | | open file : run066
beam: 118Te52+
|
|
143
|
Sat Mar 21 19:42:33 2020 |
Sergiy | Runs | run entry - run066 | | open file : run066
beam: 118Te52+
|
|
142
|
Sat Mar 21 19:11:33 2020 |
Sergiy | Runs | run entry - run065 | | open file : run065
beam: 118Te52+
|
|
141
|
Sat Mar 21 18:42:43 2020 |
Sergiy | Runs | run entry - run065 | | open file : run065
beam: 118Te52+
|
|
140
|
Sat Mar 21 18:13:22 2020 |
Shahab | General | rough comparison gas target off and on | | rough comparison of life time at 10 MeV/u
when target off with on. more noise in background
means weaker signal. |
|
139
|
Sat Mar 21 18:13:22 2020 |
Sergiy | Runs | run entry - run064 | | open file : run064
beam: 118Te52+
|
|
138
|
Sat Mar 21 17:34:10 2020 |
Sergiy | General | Recoils | |
We started recording the data from the recoils
using the MCP from Pierre-Michael's experiment. |
|
137
|
Sat Mar 21 17:32:12 2020 |
Sergiy | Runs | run entry - run064 | | open file : run064
beam: 118Te52+
|
|
136
|
Sat Mar 21 17:30:08 2020 |
Sergiy | Runs | run entry - run064 | | beam: 118Te52+
energy: 10 MeV/u
|
|
135
|
Sat Mar 21 17:21:57 2020 |
Laszlo | General | new Target density | | Ulli and Nikos managed to set the target density
to ~7E13 at 51K temperature
|
|