ID |
Date |
Author |
Category |
Subject |
Year |
539
|
Sat May 29 08:01:25 2021 |
Rene, Tino | Runs | Run 0191 | 2021 |
No. of stacks: 10 00:52:43
length SC10: 2x 5.5s
bump ge01sq2f (sc10): -20 mm
bump target (sc10): -12.8 mm
open file : e127b_run0191.lmd
beam: 118Te52+
energy: 6 MeV/u
cooler voltage:
purpose:
Fragment beam measurement (beating the record of rad. beam pg-measurement)
Detector position (Si): -25 mm
GE01DD1IG position (Scraper): +2.0 mm
run start: 08:00:39 29.05.2021
run stop: 08:58:46 29.05.2021
_______________________________________________________________________________
ON Rates
Si_ON_bdt: ~ 3 Hz
Xray_ON_bdt: ~ 120 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 380 nA
SIS particles before: 2.4e9 (one shoot)
ESR current at injection: 3.3e6 (stacked)
ESR particles after decel.: 1.5e6
Target ON density: 1.0e14 |
540
|
Sat May 29 08:59:52 2021 |
Rene, Tino | Runs | Run 0192 | 2021 |
No. of stacks: 10 00:52:43
length SC10: 2x 5.5s
bump ge01sq2f (sc10): -20 mm
bump target (sc10): -12.8 mm
open file : e127b_run0192.lmd
beam: 118Te52+
energy: 6 MeV/u
cooler voltage:
purpose:
Fragment beam measurement (beating the record of rad. beam pg-measurement)
Detector position (Si): -25 mm
GE01DD1IG position (Scraper): +2.0 mm
run start: 09:07:18 29.05.2021
run stop: 10:07:34 29.05.2021
_______________________________________________________________________________
ON Rates
Si_ON_bdt: ~ 2.5 Hz
Xray_ON_bdt: ~ 110 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 380 nA
SIS particles before: 2.7e9 (one shoot)
ESR current at injection: 3.0e6 (stacked)
ESR particles after decel.: 2.5e6
Target ON density: 1.0e14 |
541
|
Sat May 29 10:09:01 2021 |
Rene, Tino | Runs | Run 0193 | 2021 |
No. of stacks: 10 00:52:43
length SC10: 2x 5.5s
bump ge01sq2f (sc10): -20 mm
bump target (sc10): -12.8 mm
open file : e127b_run0193.lmd
beam: 118Te52+
energy: 6 MeV/u
cooler voltage:
purpose:
Fragment beam measurement (beating the record of rad. beam pg-measurement)
Detector position (Si): -25 mm
GE01DD1IG position (Scraper): +2.0 mm
run start: 10:07:35 29.05.2021
run stop: 10:59:10 29.05.2021
_______________________________________________________________________________
ON Rates
Si_ON_bdt: ~ 3 Hz
Xray_ON_bdt: ~ 110 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 380 nA
SIS particles before: 2.7e9 (one shoot)
ESR current at injection: 3.0e6 (stacked)
ESR particles after decel.: 2.5e6
Target ON density: 1.0e14 |
542
|
Sat May 29 11:01:04 2021 |
Rene, Tino | Runs | Run 0194 crap run | 2021 |
No. of stacks: 10 00:52:43
length SC10: 2x 5.5s
bump ge01sq2f (sc10): -20 mm
bump target (sc10): -12.8 mm
open file : e127b_run0194.lmd
beam: 118Te52+
energy: 6 MeV/u
cooler voltage:
purpose:
Fragment beam measurement (beating the record of rad. beam pg-measurement)
Detector position (Si): -25 mm
GE01DD1IG position (Scraper): +2.0 mm
run start: 12:22:55 29.05.2021
run stop: 12:49:05 29.05.2021
_______________________________________________________________________________
ON Rates
Si_ON_bdt: ~ 0 Hz
Xray_ON_bdt: ~ 0 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 380 nA
SIS particles before: 2.7e9 (one shoot)
ESR current at injection: 3.0e6 (stacked)
ESR particles after decel.: not measurable
Target ON density: 1.0e14 |
470
|
Wed May 26 14:48:10 2021 |
Ragan, Thanassis | Runs | Run 0134 | 2021 |
No. of stacks: 20
length SC10: 3x 5.5s
bump ge01sq2f (sc10): -20 mm
bump target (sc10): -11.5 mm
open file : e127b_run0134.lmd
beam: 118Te52+
energy: 7 MeV/u
cooler voltage:
purpose:
Fragment beam measurement (beating the record of rad. beam pg-measurement)
Detector position (Si): -25 mm
GE01DD1IG position (Scraper): +3.5 mm (20mm away from beam)
run start: 14:47:22 26.05.2021
run stop: 15:28:45 26.05.2021
_______________________________________________________________________________
ON Rates
Si_ON_bdt: ~ 8 Hz
Xray_ON_bdt: 210 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 380 nA
SIS particles before: 2.1e9 (one shoot)
ESR current at injection: 5.4e6 (stacked)
ESR particles after decel.: 0.9e6 (more or less)
Target ON density: 1.0e14 |
471
|
Wed May 26 15:30:03 2021 |
Ragan, Thanassis | General | Changing the beam energy | 2021 |
The ESR team is changing the beam energy to 6 MeV/u. |
473
|
Wed May 26 18:36:08 2021 |
Ragan, Thanassis | Runs | Run 0135 | 2021 |
No. of stacks: 20
length SC10: 3x 5.5s
bump ge01sq2f (sc10): -20 mm
bump target (sc10): -11.5 mm
open file : e127b_run0135.lmd
beam: 118Te52+
energy: 6 MeV/u
cooler voltage:
purpose:
Fragment beam measurement (beating the record of rad. beam pg-measurement)
Detector position (Si): -25 mm
GE01DD1IG position (Scraper): +1.0 mm (20mm away from beam)
run start: 18:18:10 26.05.2021
run stop: 19:07:37 26.05.2021
_______________________________________________________________________________
ON Rates
Si_ON_bdt: ~ 6 Hz
Xray_ON_bdt: 80 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 380 nA
SIS particles before: 2.1e9 (one shoot)
ESR current at injection: 5.4e6 (stacked)
ESR particles after decel.: 0.9e6 (more or less)
Target ON density: 1.0e14 |
474
|
Wed May 26 18:37:34 2021 |
Ragan, Thanassis | General | Optimization target bump/overlapp | 2021 |
| bump position | X ray bdt ON | Si rate ON |
---------------------------------------------
| -11.5 | 120 | 4-5 |
| -10.5 | 100 | 5 |
| -9.5 | 85 | 5 |
| -12.5 | 100 | 6 |
-11.5 bump position is taken for the data taking. |
475
|
Wed May 26 19:08:17 2021 |
Ragan, Thanassis | General | Cooler down | 2021 |
We stopped data taking as the electron cooler is down. |
476
|
Wed May 26 19:25:54 2021 |
Ragan, Thanassis | Runs | Run 0136 | 2021 |
No. of stacks: 20
length SC10: 3x 5.5s
bump ge01sq2f (sc10): -20 mm
bump target (sc10): -11.5 mm
open file : e127b_run0136.lmd
beam: 118Te52+
energy: 6 MeV/u
cooler voltage:
purpose:
Fragment beam measurement (beating the record of rad. beam pg-measurement)
Detector position (Si): -25 mm
GE01DD1IG position (Scraper): +1.0 mm (20mm away from beam)
run start: 19:25:38 26.05.2021
run stop: 20:25:40 26.05.2021
_______________________________________________________________________________
ON Rates
Si_ON_bdt: ~ 6 Hz
Xray_ON_bdt: 80 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 380 nA
SIS particles before: 2.1e9 (one shoot)
ESR current at injection: 5.4e6 (stacked)
ESR particles after decel.: 0.9e6 (more or less)
Target ON density: 1.0e14 |
477
|
Wed May 26 20:26:15 2021 |
Ragan, Thanassis | Runs | Run 0137 | 2021 |
No. of stacks: 20
length SC10: 3x 5.5s
bump ge01sq2f (sc10): -20 mm
bump target (sc10): -11.5 mm
open file : e127b_run0137.lmd
beam: 118Te52+
energy: 6 MeV/u
cooler voltage:
purpose:
Fragment beam measurement (beating the record of rad. beam pg-measurement)
Detector position (Si): -25 mm
GE01DD1IG position (Scraper): +1.0 mm (20mm away from beam)
run start: 20:25:44 26.05.2021
run stop: 20:33:11 26.05.2021
_______________________________________________________________________________
ON Rates
Si_ON_bdt: ~ 6 Hz
Xray_ON_bdt: 100 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 380 nA
SIS particles before: 7.0e8 (one shoot)
ESR current at injection: 5.0e6 (stacked)
ESR particles after decel.: 2.3e5 (more or less)
Target ON density: 1.0e14 |
478
|
Wed May 26 20:34:50 2021 |
Ragan, Thanassis | Detectors | Detector filling | 2021 |
Jan is filling the detector after run0137. |
479
|
Wed May 26 20:42:31 2021 |
Ragan, Thanassis | Runs | Run 0138 | 2021 |
No. of stacks: 20
length SC10: 3x 5.5s
bump ge01sq2f (sc10): -20 mm
bump target (sc10): -11.5 mm
open file : e127b_run0138.lmd
beam: 118Te52+
energy: 6 MeV/u
cooler voltage:
purpose:
Fragment beam measurement (beating the record of rad. beam pg-measurement)
Detector position (Si): -25 mm
GE01DD1IG position (Scraper): +1.0 mm
run start: 20:42:13 26.05.2021
run stop: 21:42:20 26.05.2021
_______________________________________________________________________________
ON Rates
Si_ON_bdt: ~ 5 Hz
Xray_ON_bdt: 100 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 380 nA
SIS particles before: 7.0e8 (one shoot)
ESR current at injection: 5.0e6 (stacked)
ESR particles after decel.: 2.3e5 (more or less)
Target ON density: 1.0e14 |
480
|
Wed May 26 21:42:46 2021 |
Ragan, Thanassis | Runs | Run 0139 | 2021 |
No. of stacks: 20
length SC10: 3x 5.5s
bump ge01sq2f (sc10): -20 mm
bump target (sc10): -11.5 mm
open file : e127b_run0139.lmd
beam: 118Te52+
energy: 6 MeV/u
cooler voltage:
purpose:
Fragment beam measurement (beating the record of rad. beam pg-measurement)
Detector position (Si): -25 mm
GE01DD1IG position (Scraper): +1.0 mm
run start: 21:42:25 26.05.2021
run stop: 22:42:33 26.05.2021
_______________________________________________________________________________
ON Rates
Si_ON_bdt: ~ 5-6 Hz
Xray_ON_bdt: 120 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 380 nA
SIS particles before: 7.0e8 (one shoot)
ESR current at injection: 2.0e6 (stacked)
ESR particles after decel.: 2.3e5 (more or less)
Target ON density: 1.0e14 |
481
|
Wed May 26 22:42:56 2021 |
Ragan, Thanassis | Runs | Run 0140 | 2021 |
No. of stacks: 20
length SC10: 3x 5.5s
bump ge01sq2f (sc10): -20 mm
bump target (sc10): -11.5 mm
open file : e127b_run0140.lmd
beam: 118Te52+
energy: 6 MeV/u
cooler voltage:
purpose:
Fragment beam measurement (beating the record of rad. beam pg-measurement)
Detector position (Si): -25 mm
GE01DD1IG position (Scraper): +1.0 mm
run start: 22:42:39 26.05.2021
run stop: 23:45:58 26.05.2021
_______________________________________________________________________________
ON Rates
Si_ON_bdt: ~ Hz
Xray_ON_bdt: Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 380 nA
SIS particles before: 7.0e8 (one shoot)
ESR current at injection: 3.0e6 (stacked)
ESR particles after decel.: 2.3e5 (more or less)
Target ON density: 1.0e14 |
524
|
Fri May 28 16:41:07 2021 |
Ragan, Thanassis | Runs | Run 0176 | 2021 |
No. of stacks: 10
length SC10: 2x 5.5s
bump ge01sq2f (sc10): -20 mm
bump target (sc10): -12.8 mm
open file : e127b_run0176.lmd
beam: 118Te52+
energy: 6 MeV/u
cooler voltage:
purpose:
Fragment beam measurement (beating the record of rad. beam pg-measurement)
Detector position (Si): -25 mm
GE01DD1IG position (Scraper): +2.0 mm
run start: 16:51:23 28.05.2021
run stop: 17:51:26 28.05.2021
_______________________________________________________________________________
ON Rates
Si_ON_bdt: ~4 Hz
Xray_ON_bdt: 100 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 380 nA
SIS particles before: 2.2e8 (one shoot)
ESR current at injection: 2.4e6 (stacked)
ESR particles after decel.: 3.6e5
Target ON density: 1.0e14 |
525
|
Fri May 28 17:51:54 2021 |
Ragan, Thanassis | Runs | Run 0177 | 2021 |
No. of stacks: 10
length SC10: 2x 5.5s
bump ge01sq2f (sc10): -20 mm
bump target (sc10): -12.8 mm
open file : e127b_run0177.lmd
beam: 118Te52+
energy: 6 MeV/u
cooler voltage:
purpose:
Fragment beam measurement (beating the record of rad. beam pg-measurement)
Detector position (Si): -25 mm
GE01DD1IG position (Scraper): +2.0 mm
run start: 17:51:33 28.05.2021
run stop: 18:51:36 28.05.2021
_______________________________________________________________________________
ON Rates
Si_ON_bdt: ~3-4 Hz
Xray_ON_bdt: ~100-110 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 380 nA
SIS particles before: 7.0e8 (one shoot)
ESR current at injection: 2.2e6 (stacked)
ESR particles after decel.: 6.9e5
Target ON density: 1.0e14 |
526
|
Fri May 28 18:52:00 2021 |
Ragan, Thanassis | Runs | Run 0178 | 2021 |
No. of stacks: 10
length SC10: 2x 5.5s
bump ge01sq2f (sc10): -20 mm
bump target (sc10): -12.8 mm
open file : e127b_run0178.lmd
beam: 118Te52+
energy: 6 MeV/u
cooler voltage:
purpose:
Fragment beam measurement (beating the record of rad. beam pg-measurement)
Detector position (Si): -25 mm
GE01DD1IG position (Scraper): +2.0 mm
run start: 18:51:44 28.05.2021
run stop: 19:51:50 28.05.2021
_______________________________________________________________________________
ON Rates
Si_ON_bdt: ~4-5 Hz
Xray_ON_bdt: ~110 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 380 nA
SIS particles before: 2.0e9 (one shoot)
ESR current at injection: 2.3e6 (stacked)
ESR particles after decel.: 6.9e5
Target ON density: 1.0e14 |
527
|
Fri May 28 19:52:09 2021 |
Ragan, Thanassis | Runs | Run 0179 | 2021 |
No. of stacks: 10
length SC10: 2x 5.5s
bump ge01sq2f (sc10): -20 mm
bump target (sc10): -12.8 mm
open file : e127b_run0179.lmd
beam: 118Te52+
energy: 6 MeV/u
cooler voltage:
purpose:
Fragment beam measurement (beating the record of rad. beam pg-measurement)
Detector position (Si): -25 mm
GE01DD1IG position (Scraper): +2.0 mm
run start: 19:51:51 28.05.2021
run stop: 20:37:04 28.05.2021
_______________________________________________________________________________
ON Rates
Si_ON_bdt: ~4-5 Hz
Xray_ON_bdt: ~ 110 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 380 nA
SIS particles before: 2.4e9 (one shoot)
ESR current at injection: 2.6e6 (stacked)
ESR particles after decel.: 6.9e5
Target ON density: 1.0e14 |
528
|
Fri May 28 20:37:42 2021 |
Ragan, Thanassis | Runs | Run 0180 | 2021 |
No. of stacks: 10
length SC10: 2x 5.5s
bump ge01sq2f (sc10): -20 mm
bump target (sc10): -12.8 mm
open file : e127b_run0180.lmd
beam: 118Te52+
energy: 6 MeV/u
cooler voltage:
purpose:
Fragment beam measurement (beating the record of rad. beam pg-measurement)
Detector position (Si): -25 mm
GE01DD1IG position (Scraper): +2.0 mm
run start: 20:54:46 28.05.2021
run stop: 21:53:27 28.05.2021
_______________________________________________________________________________
ON Rates
Si_ON_bdt: ~ 4-5 Hz
Xray_ON_bdt: ~ 120 Hz
BaF_OR: ---
Si voltage: 100.0 V
Si leakage current: 380 nA
SIS particles before: 2.4e9 (one shoot)
ESR current at injection: 2.6e6 (stacked)
ESR particles after decel.: 6.9e5
Target ON density: 1.0e14 |