Time | SIS-intensity | cooler-HV | LMD-DAQ1 | LMD-DAQ2
|
02.30 | ? | ? | Th227781-Th227784 | 0027-0028
|
03.03 | 1.75e9 | 209648 | 7785-7787 | 0029-0030
|
03:28 | 1.7e9 | 209648 | 7788 | 0031 (stopped during scan)
|
Break - fixing cables, Elog ID: 125
|
04:00 - problems with UNILAC, stopping for now.
|
Apparently not so bad problems. we can continue.
|
Mesytek PS of xuv-detector crashed, can only be restarted from inside the ESR by turning the crate on and off.
|
05.20 | 1.23e9 | 209646 | 7791-7794 | 0035-0038
|
05.52 | 1.5e9 | 209648 | 7795-7797 | 0039-0042
|
06.24 | 1.5e9 | 209642 | 7798-7800 | 0043-0046 | 1 sec waiting at each laser frequency (dwell time 30)
|
07.36 | xx e9 | 209 xx | 7803-7804 | 0047-0050 | problems with DAQ 1 and DAQ2
|
07.52 | xx e9 | 209646 | 7805-7809 | 0051-0055 | DAQs started again | 5 sec waiting at each laser frequency (dwell time 150)
|
08.30 | e9 | 209 xx | 7810-78 | 0056-00 | DAQs started again | 5 sec waiting at each laser frequency (dwell time 150)
|
|