DAQ1: lxg1927:/data.local2/BeamTimeTh22/
DAQ2: lxg0155:/data.local2/E142/
LMD file name DAQ1:229Thor
LMD file name DAQ2:229Th
Shottky and NTCAP started at 23:53, center freq. 242.2M, 10MIQs, -30dBm
Shottky marker pos: 243.973MHz
Time | SIS-intensity | cooler-HV | LMD-DAQ1 | LMD-DAQ2 | scan range(nm) | step width(nm) | dwell time(s) | comments
|
00:20 | 1.4e9 | 209617 | 0065-0067 | 7810 | 323.2-321.2 | 0.01 | 4 | buggy DAQ? see Elog, file 0068 empty
|
01:27 | 1.6e9 | 209606 | 0069-0070 | 7811 | 323.2-321.2 | 0.01 | 4 | buggy DAQ? see Elog, file 0071 empty
|
02:15 | 1.6e9 | 209611 | 0072-0073 | 7812 | 323.2-321.2 | 0.01 | 4 | buggy DAQ? see Elog, file 0074-0075, 7813-7814 empty
|
03:00 | 1.1e9 | ? | 0076-0077 | 7815 | 323.2-321.2 | 0.01 | 4 | buggy DAQ? see Elog and below, file 0078, 7816 empty
|
We were searching for a difference of a factor of twoin both DAQs. It turns out that the default value for the MBSstream server task is scale=2. In the main task this value is explicately set to scale=1. we will now (starting with filenumber: 0078) restart the 2nd DAQ with set stream_serv scale=1.
Also TDC is disabled.
From file number 0076 in DAQ2 : ADC thresholds:
unsigned short caen_V785AH_threshold_mod0 [32] =
{0x0100 , 0x0005 , 0x0004 , 0x0003 , 0x0004 , 0x0003 , 0x0005 , 0x0003 ,
0x0005 , 0x0004 , 0x0100 , 0x0100 , 0x0100 , 0x0100 , 0x0100 , 0x0100 ,
0x0100 , 0x0100 , 0x0100 , 0x0100 , 0x0100 , 0x0100 , 0x0100 , 0x0100 ,
0x0100 , 0x0100 , 0x0100 , 0x0100 , 0x0100 , 0x0100 , 0x0100 , 0x0100 };
Before the next scan, we realized, that the laser destabilized. For the rest of the shift we tried to get laser back online (see ID:149). |