HOME ESR EXPERIMENTS LABS etc
E121 E127 E132 E125 E143 laser_cooling_2021 E142 Ê128 E146 E0052 E0018 E0028 E0038
  Nuclear hyperfine mixing in 229Th89+  Not logged in ELOG logo
Message ID: 15     Entry time: Thu Mar 10 15:20:26 2022
Author: Jan  
Category: DAQ 
Subject: analog branch signal patches to Messhütte  
The additional signals from PMTs and XUV detector needed for spectroscopic analysis in the second DAQ are patched to AP Messhütte (MH) via the red patch panel at the inside of the target region. The patch channels F1 to F8 (also labeled A to H in red on white) are used and extended by a cable bundle to reach below the mirror chamber. Inside the MH the signals arrive at the red patch panel and are forwarded to the blue patch panel close to the laser DAQ using channels 1 to 8 (also labeled A to H).
 
The entire connection for these 8 channels from the mirror chamber to the blue panel has been tested with a pulser signal of ~115mV amplitude. After transfer the amplitude has decreased to ~40mV, see also attached fotos.

The signal transport time from the mirror chamber to the blue panel is ~407 ns. This was measured by patching a logic puls from ESR to MH and back to ESR, as show in the delay_ESR... foto attached.  
Attachment 1: red_panel_ESR.jpg  2.883 MB  | Hide | Hide all | Show all
red_panel_ESR.jpg
Attachment 2: pulser_signal_ESR.jpg  2.818 MB  | Show | Hide all | Show all
Attachment 3: pulser_signal_MH.jpg  3.463 MB  | Hide | Hide all | Show all
pulser_signal_MH.jpg
Attachment 4: delay_ESR-MH-ESR.jpg  3.813 MB  | Show | Hide all | Show all
Attachment 5: cable_bundle_mirror_chamber.jpg  4.920 MB  | Show | Hide all | Show all
ELOG V3.1.5-fc6679b