HOME ESR EXPERIMENTS LABS etc
E121 E127 E132 E125 E143 laser_cooling_2021 E142 Ê128 E146 E0052 E0018
  Nuclear hyperfine mixing in 229Th89+  Not logged in ELOG logo
Message ID: 207     Entry time: Mon Apr 11 10:31:07 2022
Author: Kristian, Sebastian, Alexandre, Danyal, Paul 
Category: General 
Subject: new laser wavelength scan range 322.41 - 322.00 nm 
new wavelength scan range is 322.41 - 322.00 nm

at 10:31

TimeSIS-intensitycooler-HVLMD-DAQ1 file nr LMD-DAQ2 file nr scan range(nm)step width(nm)dwell time(s)particles countedcomments
10:31 1.75e9 209617 0180 7915 322.41 - 322.00 0.002 5s 2300 ABORT ... no laser ... beam stabilization was off
10:40 xxe9 209617 0181 7916 322.41 - 322.00 0.002 5s xxx ABORT ... laser did not start from 322.41 nm
10:42 xxe9 209615 0182 7917 322.41 - 322.00 0.002 5s xxx ABORT ... laser did not start from 322.41 nm
10:45 2.1e9 209616 0183 7918 322.41 - 322.00 0.002 5s 9236 HV E-cooler fluctuates slowly over 3 V
11:22 1.7e9 209616 0184 7919 322.41 - 322.00 0.002 5s xxx
12:02 2.0e9 209616 0185 7920 322.41 - 322.00 0.002 5s 9660
12:43 1.8e9 209618 0186 7921 322.41 - 322.00 0.002 5s 6533 HV E-cooler jump to ~209700k for ~10 seconds and than back to 209618
13:24 2.0e9 209617 0187 7922 322.41 - 322.00 0.002 5s 9500
14:05 2.0e9 209618 0188 7923 322.41 - 322.00 0.002 5s 9220
ELOG V3.1.5-fc6679b