HOME ESR EXPERIMENTS LABS etc
E121 E127 E132 E125 E143 laser_cooling_2021 E142 Ê128 E146 E0052 E0018
  Nuclear hyperfine mixing in 229Th89+  Not logged in ELOG logo
Message ID: 210     Entry time: Mon Apr 11 14:45:11 2022
Author: Paul, Konstantin, Sarper, David 
Category: Runs 
Subject: Afternoon shift runs 11.04 
We continue scan the new wavelength scan range is 322.41 - 322.00 nm



TimeSIS-intensitycooler-HVLMD-DAQ1 file nr LMD-DAQ2 file nr scan range(nm)step width(nm)dwell time(s)particles countedcomments
14:45 1.9e9 209618 0189 7924 322.41 - 322.00 0.002 5s 9100
18:54 1.83e9 209616 0191 7926 322.41 - 322.00 0.002 5s 7300
19:34 1.7e9 209615 0192 7927 322.41 - 322.00 0.002 5s 7110
20:13 1.8e9 20961X 0193 7928 322.41 - 322.00 0.002 5s 6730
20:53 1.8e9 209614 0194 7929 322.41 - 322.00 0.002 5s 7550 During the scan the ecooler voltage changed to approximately 209613
21:43 1.7e9 209614 0195 7931 322.41 - 322.00 0.002 5s 7000
22:30 1.6e9 209612 0197 7932 322.41 - 322.00 0.002 5s 7300
23:10 1.4e9 209614 0198 7933 322.41 - 322.00 0.002 5s 6100 For this measurement, ESR_Ring went red, we realized only after completing the measurement. The sections went red are Dipole Correction Points (GE01KP17-18-19-20, 4 in total) @~23:45 and fixed @01:35...
01:52 1.6e9 209614 0199 7934 322.41 - 322.00 0.002 5s 7151
02:32 1.7e9 209616 0200 7935 322.41 - 322.00 0.002 5s 8368
03:22 1.8e9 209617 0201 7936 322.41 - 322.00 0.002 5s 7005
04:01 1.9e9 209616 0202 7937 322.41 - 322.00 0.002 5s Ecooler voltage increased 4 volts during the run
ELOG V3.1.5-fc6679b