HOME ESR EXPERIMENTS LABS etc
E121 E127 E132 E125 E143 laser_cooling_2021 E142 Ê128 E146 E0052 E0018 E0028 E0038
  Nuclear hyperfine mixing in 229Th89+  Not logged in ELOG logo
Entry  Tue Apr 12 13:24:40 2022, Alexandre, Sebastian, Detectors, Sideband in Schottky IMG_20220412_125530_resized_20220412_125736155.jpgIMG_20220412_125643_resized_20220412_125736537.jpg
    Reply  Tue Apr 12 14:11:52 2022, Ragan, Detectors, Sideband in Schottky 
Message ID: 218     Entry time: Tue Apr 12 14:11:52 2022     In reply to: 217
Author: Ragan 
Category: Detectors 
Subject: Sideband in Schottky 
> Sometimes we see a broad sideband at lesser Schottky frequencies to the high-intensity thorium beam.
> 
> Pic 1 shows the relative broad sideband on the left.
> 
> Pic 2 depicts the vanishing of the sideband after ~1-2 minutes.


These are not the sidebands. Maybe some short-lived fragments survive even after the scrapers are used?
ELOG V3.1.5-fc6679b