HOME ESR EXPERIMENTS LABS etc
E121 E127 E132 E125 E143 laser_cooling_2021 E142 Ê128 E146 E0052 E0018
  Nuclear hyperfine mixing in 229Th89+  Not logged in ELOG logo
Message ID: 236     Entry time: Sat Apr 16 04:19:05 2022
Author: Patrick, Simon, Alex, Sarper 
Category: Runs 
Subject: Runs night + morning shifts 16.04. 
Runs of the night shift 16.04. after changing the wavelength range. The new range is 320.12 - 319.859 nm. The step size was decreased from 0.002 nm to 0.001 nm.
The goal was to have the same number of scans as before (261), however, the scan range in the labview program could not be set accordingly. We decided to go with 262 scans after the first run.


TimeSIS-intensitycooler-HVLMD-DAQ2 file nr LMD-DAQ1 file nr scan range(nm)step width(nm)dwell time(s)particles countedcomments
04:24 1.28e9 209616 0338 8051 320.12 - 319.86 0.001 5s 6750 This run had only 260 scans
05:18 1.20e9 209615 0339 8052 320.12 - 319.859 0.001 5s 6300 First run with 262 scans
06:09 1.36e9 209615 0340 8053 320.12 - 319.859 0.001 5s 6910 laser scan started 2 min late at 650 counts
07:03 1.24e9 209615 0341 8054 320.12 - 319.859 0.001 5s 6330
07:59 1.23e9 209615 0342 8055 320.12 - 319.859 0.001 5s 5712
08:51 1.1e9 209615 0343 8056 320.12 - 319.859 0.001 5s 4380
09:44 1.28e9 209615 0344 8057 320.12 - 319.859 0.001 5s 5135
10:39 1.25e9 209615 0345 8058 320.12 - 319.859 0.001 5s 5860
11:30 1.2e9 209615 0346 8059 320.12 - 319.859 0.001 5s 6500
12:22 1.23e9 209618 0347 8060 322.41 - 322.00 0.002 5s 5200 Laser wavelength scan range is changed to 322.41 - 322.00 nm and increment to 0.002 nm.
13:04 1.2e9 209616 0348 8061 322.41 - 322.00 0.002 5s 4411
13:50 1.2e9 209616 0349-0351 8062-8063 322.41 - 322.00 0.002 5s 10651 last scan / 10 loops ~ 3 hours of scan -- Ecooler failed, realized at 16:05 we were on loop8, laser is turned off at 16:10
ELOG V3.1.5-fc6679b