made sure that the extra 20dB amplifier is off.
still in the search of 70-Se
the new setting is roughly 400 khz lower in frequency. Previous beam time Ge was on 243.100 now it is on 242.74 we decided to use the higher harmonic: expecting it on 244.66 MHz
still no beam in ESR: quadrupole magnets are down
turned on extra 20dB amplifier for the 245 Resonator around 12:32
Data is being shared on the WWW server. Time difference between the analyzers is in order of seconds: time stamp of the 245MHz data is leading those of 410MHz by 21.733 [s]
current scraper positions suggested by Sergey: GEEXDS2HA = -11mm GE01DS-H (innen) = -58mm
DAQs and NTCAP
increase factor 4 in power for 410 before: 410MHz-2021.07.01.18.48.07.516.tiq.png after: 410MHz-2021.07.01.19.23.49.099.tiq.png
Up to now, attempts to cool the fat line between Se and Ar were conducted. We give up it now and remove cooling
new sextupole setting, isomer not visible yet.
Variation of quadrupole E01QS03D to change gamma_t in isoc. mode measured with 78Kr at 368.5 MeV/u on 28.06.2021 evening. The shape of the three curves looks very similar they would only require a different beam velocity. But I suppose we stay with the value close to the old one (gamma_t ~ 1.3956).
Beam is secondary beam now. The intensity is lower. Change reference level to -50dBm. Carrier frequency:245MHz IQ rate(S/s): 20M. Reference Level: -50 dBm. Start taking data. SC_2021-05-06_23_02_46 IQ_2021-05-06_23_02_33
Reference Level: -40 dBm. Start taking data. SC_2021-05-07_00-06-57 IQ_2021-05-07_00-06-57