HOME ESR EXPERIMENTS LABS etc
NucAR lab laser_lab Fritz-Bosch-Lab X-Ray Lab target Beavertail
  NucAR lab  Not logged in ELOG logo
Message ID: 17     Entry time: Fri Jan 27 10:18:16 2023
Author: Jan Glorius, Rebanna Klawitter, Emily Voigt 
Category: Detectors 
Subject: DSSD-Performance-Test 
Detector: W1 3305-09 
Setup: 
- on vacuum (p=5e-5mbar)
- dark chamber
- triple alpha source

Daten: Lxg1275:/data.local2/2023_dssd_test/messung001.lmd

The resolution (sigma) is consistently below 0.5% for all strips.

dE/E = sigma/mean (root analysis)

strip dE/E
y1 0.0040
y2 0.0043
y3 0.0037
y4 0.0034
y5 0.0037
y6 0.0035
y7 0.0044
y8 0.0034
y9 0.0037
y10 0.0035
y11 0.0037
y12 0.0033
y13 0.0038
y14 0.0036
y15 0.0046
y16 0.0035

x1 0.0050
x2 0.0041
x3 0.0042
x4 0.0045
x5 0.0042
x6 0.0036
x7 0.0041
x8 0.0041
x9 0.0039
x10 0.0040
x11 0.0038
x12 0.0035
x13 0.0043
x14 0.0038
x15 0.0044
x16 0.0036
Attachment 1: alphaE1.pdf  14 kB  Uploaded Fri Jan 27 16:30:22 2023  | Show | Hide all | Show all
Attachment 2: alphaE2.pdf  24 kB  Uploaded Fri Jan 27 16:30:28 2023  | Hide | Hide all | Show all
alphaE2.pdf
Attachment 3: alphaE_x_vs_Y.pdf  45 kB  Uploaded Fri Jan 27 16:30:33 2023  | Show | Hide all | Show all
Attachment 4: alphaE_x_vs_Y_lin.pdf  743 kB  Uploaded Fri Jan 27 16:30:37 2023  | Hide | Hide all | Show all
alphaE_x_vs_Y_lin.pdf
Attachment 5: alphaE_x_vs_Y_log.pdf  1.041 MB  Uploaded Fri Jan 27 16:30:41 2023  | Hide | Hide all | Show all
alphaE_x_vs_Y_log.pdf
Attachment 6: alphaE_x_vs_Y_log_full.pdf  1.051 MB  Uploaded Fri Jan 27 16:30:45 2023  | Hide | Hide all | Show all
alphaE_x_vs_Y_log_full.pdf