  1   Thu Jul 27 15:18:52 2023 Jan GloriusStatus UpdateEgelhof pocket & drive unmounted
The detector pocket and the pneumatic drive installed on the inside of HITRAP septum (position 2, close to the dipole) was unmounted and will be stored by ESR crew (Uli Popp, Jürgen Krieg). 

The pocket was leaking inside and had to be maintained at fore-vacuum for ring operation.
Attachment 1: IMG_20230727_133153568.jpg
IMG_20230727_133153568.jpg
Attachment 2: IMG_20230727_133211222.jpg
IMG_20230727_133211222.jpg
Attachment 3: status_now.jpg
status_now.jpg
Attachment 4: previously.JPG
previously.JPG
  2   Thu Jul 27 15:29:21 2023 Jan GloriusStatus Updatezero-degree pocket @ target unmounted
The zero-degree pocket and stepper motor drive installed on an outside flange (bare flange on last foto attached) of the interaction chamber has been unmounted. The reason is actually unknown to me...

At the moment the drive and pocket are stored inside the ESR on a palette. Might be stored elsewhere in the future, ESR crew (Uli Popp, Jürgen Krieg) will do this eventually.
Attachment 1: IMG_20230727_133615229.jpg
IMG_20230727_133615229.jpg
Attachment 2: IMG_20230727_133633696.jpg
IMG_20230727_133633696.jpg
Attachment 3: IMG_20230727_133803959.jpg
IMG_20230727_133803959.jpg
Attachment 4: A2.jpg
A2.jpg
Attachment 5: A3.jpg
A3.jpg
Attachment 6: A4.jpg
A4.jpg
  3   Thu Jul 27 16:28:19 2023 Jan GloriusStatus Updateunmounted drive after mirror chamber
The pneumatic drive, that was installed on the outside flange (see the blind flange on the attached foto below) and used for Alex Gumberidze's diamond detectors in the past, is now unmounted.

The bellow was leaking, treated with vacseal and had to be removed.

This drive will be installed at the interaction chamber on a zero-degree port (outside) with a new bellow (for E028).
Attachment 1: B2.jpg
B2.jpg
Attachment 2: B3.jpg
B3.jpg
Attachment 3: IMG_20230727_133820910.jpg
IMG_20230727_133820910.jpg
  4   Thu May 9 11:17:47 2024 Jan GloriusStatus UpdateGEEXDD2AG - new ppos drive
A new pneumatic detector drive was installed at the target chamber. The flange is perpendicular to the beam and positioned outside the ring downstream of the jet. 

Nomenklatur (ID): GEEXDD2AG

Coordinates: -10000 to +3100 (roughly) 

The coordinates have an offset, the real zero (beam) is somewhere between 2000 and 3100.

Control System status: not yet published to device control or paramodi. Use Equip State App for testing.