HOME ESR EXPERIMENTS LABS etc
E121 E127 E132 E125 E143 laser_cooling_2021 E142 Ê128 E146 E0052 E0018
  Laser Cooling Experiment 2021, Page 4 of 5  Not logged in ELOG logo
ID Date Authorup Category Subject Text Attachments
  70   Sun May 16 02:18:53 2021 SebastianGeneralUV Drop1:25 a.m. huge drop in UV laser power
-> small crystal bump with both y screws
of bbo oven
  
  Draft   Sun May 16 02:20:58 2021 SebastianGeneral"Der Laser ist (wieder) ok"    
  72   Sun May 16 02:22:19 2021 SebastianGeneral"Der Laser ist ok"    
  63   Sat May 15 09:22:41 2021 Sebastian AcceleratorEkühler Settings für Ekühler an und aus in SC4 und

5
 IMG-20210515-WA0000.jpgB5FE1031-7FFD-44D3-92B0-75E0784718D9.jpeg 
  44   Fri May 14 01:34:44 2021 TeamGeneralstrange XUV Anode signalWe see a strange behavior of the anode signal
when we bunch the ion beam and electron cooler
is on.
 Screenshot_(68).png 
  59   Fri May 14 22:04:25 2021 TeamAcceleratorESR OPEN ; NO BEAM -> Reset cooling devicewe had to open the ESR to reset a cooling
device
  
  60   Fri May 14 22:20:37 2021 TeamAcceleratorESR Closed - BEAM #ON!    
  61   Sat May 15 03:39:16 2021 TeamGeneralactual revolution frequencyfrev = 1,2912735 MHz   
  65   Sat May 15 09:50:31 2021 TeamRunsLaser cooling of.... H=2
H=7
H=10
  
  73   Sun May 16 02:28:21 2021 TeamGeneral#Beam ON!Laser specs:
pulse length -> 482ps
  
  74   Sun May 16 05:09:04 2021 TeamGeneralLaser cooling with 482pswe see laser cooling with 482ps pulse length   
  75   Sun May 16 05:09:27 2021 TeamGeneralSwitch to 285pspulse length -> 285ps

minimum 62mW inside ESR (depending on laser
  
  76   Sun May 16 05:24:00 2021 TeamGeneralLaser cooling with 285pswe also see laser cooling with 285ps pulse
length
  
  77   Sun May 16 06:13:46 2021 TeamGeneralSwitch to 166ps     
  78   Sun May 16 07:03:07 2021 TeamGeneralLaser cooling with 166psWe saw some indications of laser cooling @
166ps pulse length
  
  81   Sun May 16 21:23:02 2021 TeamGeneralESR OPEN -> preparation for Polarisation Tests    
  82   Sun May 16 22:11:49 2021 TeamGeneralLaser Polarisation valuesmaximal transmission of PBSC (257/514 pbsc
was used in combination with xlp12 detector
and visual on a screen):
  
  83   Mon May 17 08:05:42 2021 TeamGeneralEnd of beamtime~ 8 a.m.   
  45   Fri May 14 04:50:46 2021 Team #NightGeneralScraper Tests Ion / Laser Beamlaser is 4-6mm below the ion beam.
It could be that the interaction between
both beams came only from the interaction
  
  46   Fri May 14 06:34:45 2021 Team #NightAnalysisDSG821 IP140.181.104.108   
ELOG V3.1.5-fc6679b