Entry  Wed May 12 10:15:47 2021, Volker Hannen, DAQ, Unplugged TDC inputs for MCP front and back 
To reduce the load on the VUPROM TDC, we unplugged the TDC inputs for the front and back signals of the MCP of the XUV detector.
The Anode signal is still plugged in and should be sufficient for the analysis.
Entry  Fri May 14 04:50:46 2021, Team #Night, General, Scraper Tests Ion / Laser Beam 
laser is 4-6mm below the ion beam.
It could be that the interaction between both beams came only from the interaction between the laser halo with the ion beam ?!
Entry  Fri May 14 06:34:45 2021, Team #Night, Analysis, DSG821 IP 
140.181.104.108
Entry  Fri May 14 06:35:55 2021, Team #Night, General, Adjustment of Laser 
we increased the height of the laser beam

TEM Settings
Entry  Fri May 14 07:20:18 2021, Team #Night, General, actual bunching frequency 
25,82556 MHz
h = 20
Entry  Fri May 14 07:33:42 2021, Team #Night, General, ecooler central frequency shifted relative to bunch central frequency 
 
Entry  Fri May 14 01:34:44 2021, Team, General, strange XUV Anode signal Screenshot_(68).png
We see a strange behavior of the anode signal when we bunch the ion beam and electron cooler is on.

peak structure... ---> we play now with the bunching amplitude 
Entry  Fri May 14 22:04:25 2021, Team, Accelerator, ESR OPEN ; NO BEAM -> Reset cooling device 
we had to open the ESR to reset a cooling device
Entry  Fri May 14 22:20:37 2021, Team, Accelerator, ESR Closed - BEAM #ON! 
 
Entry  Sat May 15 03:39:16 2021, Team, General, actual revolution frequency 
frev = 1,2912735 MHz
Entry  Sat May 15 09:50:31 2021, Team, Runs, Laser cooling of....  
H=2
H=7
H=10
Entry  Sun May 16 02:28:21 2021, Team, General, #Beam ON! 
Laser specs:
pulse length -> 482ps
Entry  Sun May 16 05:09:04 2021, Team, General, Laser cooling with 482ps 
we see laser cooling with 482ps pulse length
Entry  Sun May 16 05:09:27 2021, Team, General, Switch to 285ps 
pulse length -> 285ps

minimum 62mW inside ESR (depending on laser wavelength)
Entry  Sun May 16 05:24:00 2021, Team, General, Laser cooling with 285ps 
we also see laser cooling with 285ps pulse length
Entry  Sun May 16 06:13:46 2021, Team, General, Switch to 166ps  
 
Entry  Sun May 16 07:03:07 2021, Team, General, Laser cooling with 166ps 
We saw some indications of laser cooling @ 166ps pulse length
Entry  Sun May 16 21:23:02 2021, Team, General, ESR OPEN -> preparation for Polarisation Tests 
 
Entry  Sun May 16 22:11:49 2021, Team, General, Laser Polarisation values 
maximal transmission of PBSC (257/514 pbsc was used in combination with xlp12 detector and visual on a screen):

L/4 @ 276° & L/2 @ 348°                -->   p-polarized light
Entry  Mon May 17 08:05:42 2021, Team, General, End of beamtime 
~ 8 a.m.