  Laser Cooling Experiment 2021, Page 1 of 5  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
ID Date Author Category Subjectdown
  30   Thu May 13 00:58:53 2021 DanyalDAQunbunched ion beam
Attachment 1: not_bunched_-_signal.jpg
not_bunched_-_signal.jpg
Attachment 2: not_bunched_-_Schottky.jpg
not_bunched_-_Schottky.jpg
  44   Fri May 14 01:34:44 2021 TeamGeneralstrange XUV Anode signal
We see a strange behavior of the anode signal when we bunch the ion beam and electron cooler is on.

peak structure... ---> we play now with the bunching amplitude 

200mV
150mV
100mV ---> Peaks higher?

see attached file
Attachment 1: Screenshot_(68).png
Screenshot_(68).png
  20   Wed May 12 13:11:58 2021 DanyalAcceleratorshort break between 13:30 and 15:30
There will be a short break (2 hours) this afternoon. Between 13:30 and 15:30. 
The so-calles "super lense" in the UNILAC needs to be cleaned (rinsed). 
After that operation should continue as usual. 
  2   Tue May 11 15:49:30 2021 DanyalGeneralsetting up ESR
The operators are still busy extracting the beam from the SIS18 towards the ESR and injecting it into the ESR. 
  32   Thu May 13 01:05:45 2021 DanyalDAQmore stability by bunching
Because the C3+ part of the ion beam is properly bunched, it is no longer so sensitive to the drifts caused by the e-cooler. 
In the O4+ part of the ion beam these drifts can still be seen. 
  8   Wed May 12 02:34:29 2021 DanyalGeneralinstabilities in ion frequency
The ion beam moves around, pretty arbitrary. See picture. 
ESR crew believes that it is not due to fluctuations in the HV of the E-Cooler. 
Attachment 1: fluctuations.jpg
fluctuations.jpg
  10   Wed May 12 08:10:17 2021 LarsGeneralinstabilities in ion frequency
looks like the E-Cooler is responsible for this. If one turns off the electron current, the beam stays stable. 
M.Steck is informed.

> The ion beam moves around, pretty arbitrary. See picture. 
> ESR crew believes that it is not due to fluctuations in the HV of the E-Cooler. 
  21   Wed May 12 15:36:04 2021 DanyalAcceleratorgeneral power failure in ESR! (everything is off)
The power in the ESR is off. 
(also on the gas-target area on top of ESR)
Electrical engineers are trying to find and fix the problem. 
  25   Wed May 12 22:35:33 2021 DanyalGeneralfrev and fb
Schottky frequency (189th harmonic) = 244.033662 MHz

revolution frequency  frev = 1.2911834 MHz

bunching frequency h=2  --> fb = 2.582367 MHz
bunching frequency h=10  --> fb = 12.911834 MHz
  11   Wed May 12 08:32:04 2021 SebastianAnalysisfluorescence & energetic overlap
During the night shift we saw several rises of the fluorescence (see another entry) and also energetic overlap in coasting beam modus.
Here the laser wavelength was stabilized @ 1028,967nm and electron cooler was switched off because of some fluctuations which we saw in the schottky.
Left part of the schottky picture shows the c3+ beam, the right part is the o4+ contamination.
Attachment 1: Screenshot_(154).png
Screenshot_(154).png
  5   Tue May 11 18:29:35 2021 DanyalGeneralfirst ions in the ESR
Attachment 1: first_ions_are_injected.jpg
first_ions_are_injected.jpg
  Draft   Fri May 14 07:33:42 2021 Team #NightGeneralecooler central frequency shifted relative to bunch central frequency
  31   Thu May 13 01:01:27 2021 DanyalDAQbunched ion beam
Attachment 1: bunched_-_signal.jpg
bunched_-_signal.jpg
Attachment 2: bunched_-_Schottky.jpg
bunched_-_Schottky.jpg
Attachment 3: zoom_bunched_-_Schottky.jpg
zoom_bunched_-_Schottky.jpg
  6   Tue May 11 20:14:43 2021 DanyalGeneralbad ESR vacuum
I just heard that the ESR vacuum is quite bad. 
There was a small vacuum problem a while ago, it was sealed, but apparently the pressure is not as low as usual.

Markus Steck said that the beam lifetime is only 15 - 20 seconds !!! 

This will seriously complicate some of our test experiments :( 
  61   Sat May 15 03:39:16 2021 TeamGeneralactual revolution frequency
frev = 1,2912735 MHz
  48   Fri May 14 07:20:18 2021 Team #NightGeneralactual bunching frequency
25,82556 MHz
h = 20
  85   Tue May 31 07:29:11 2022 KenDetectorsXUV-Detektor
Rate was very low: ~ 100Hz
Adjusted Walk level and Threshold, new rate: 5kHz
Additionally, parameters of the detector were varied for optimization but were returned to default afterwards.
  42   Thu May 13 23:42:37 2021 Ken UeberholzGeneralWhat was done
In this shift a number of successful Schottky measurements were done:
With fixed laser wavelength, while varying the wavelength, with different bunching and more (see logfile 1 for more info: line 53 to at least 107).
The detector software sometimes files to change the current of the power supplies, if this happens a simple restart of the GUI fixes the problem.
Once in this shift the Mesytek in the laser lab turned itself (?) off and the background rate increased. Hopefully this was a single event.
Attachment 1: Schottky1.jpeg
Schottky1.jpeg
Attachment 2: Schottky2.jpeg
Schottky2.jpeg
Attachment 3: Schottky3.jpeg
Schottky3.jpeg
Attachment 4: Schottky4.jpeg
Schottky4.jpeg
  39   Thu May 13 18:34:54 2021 Ken UeberholzGeneralWhat happened scince shift change at 4pm
Ion frequency shifts with laser, both manually and scanned, without bunches: successful
Bunching with 7 and 20 bunches: successful
Tried laser scans with bunches: unsuccessful
Manual laser scans with bunches: successful
  28   Wed May 12 23:36:18 2021 Ken UeberholzDAQVI change
carbon main vi - kopie is now in operation

here, in keysight.vi the input settings for the new impedence for the multimeter are now hopefully correct --> THIS SHOULD BE CHECKED IF THE RING IS OPEN 