Entry  Wed May 12 22:28:55 2021, Ken Ueberholz, General, Bunching succesfull 
Bunching with 2 and 10 bunches succesfull
Entry  Wed May 12 19:48:24 2021, Sebastian, General, DSG821 Network IMG_20210512_195329_resized_20210512_075346417.jpg
To implement the bunch Signal Generator (DSG821 inside ESR) you have to:

1. unplug the Ethernet cable
2. under System / io config set the ip address
3. set Sub mask
4. set DNS
5. very important: than press Apply!
6. plug in Ethernet cable
7. than a message like "successfully connected to network" should show up
8. you can crosscheck the Settings by pressing the "eye symbol"
Entry  Wed May 12 18:59:15 2021, Ken Ueberholz, General, Power is back 
Power is back and most things are running again
Entry  Wed May 12 15:36:04 2021, Danyal, Accelerator, general power failure in ESR! (everything is off) 
The power in the ESR is off. 
(also on the gas-target area on top of ESR)
Electrical engineers are trying to find and fix the problem. 
Entry  Wed May 12 13:11:58 2021, Danyal, Accelerator, short break between 13:30 and 15:30 
There will be a short break (2 hours) this afternoon. Between 13:30 and 15:30. 
The so-calles "super lense" in the UNILAC needs to be cleaned (rinsed). 
After that operation should continue as usual. 
Entry  Wed May 12 10:15:47 2021, Volker Hannen, DAQ, Unplugged TDC inputs for MCP front and back 
To reduce the load on the VUPROM TDC, we unplugged the TDC inputs for the front and back signals of the MCP of the XUV detector.
The Anode signal is still plugged in and should be sufficient for the analysis.
Entry  Wed May 12 10:14:18 2021, Lars, Accelerator, E-Cooler 
M.Steck et al. discussed about the E-Cooler and found a possible issue. They asked for enterance to the ESR. Since nobody else was in the HKR and anyway nothing was running because of some other issues, I told, the experiment would not be disturbed and they could enter and do things. (Sth. like putting some repeller electrodes onto hand and other magical things).
It should take about 10 Minutes and might be already finished by now.
Entry  Wed May 12 09:59:08 2021, Benedikt, General, Rigol DSG821 signal generator settings CF7701F6-86BE-406C-8FAD-F3161463181C.jpeg
 
Entry  Wed May 12 09:09:15 2021, Sebastian, DAQ, Fluorescence 1029967nm.png
fluorescence with detector in parking position
fixed laser wavelength
electron cooling ON, 
BUT we saw strange drifts in the Schottky spectra. It seems to be that these drifts come from the electron cooler! are the drift tubes grounded?

the drifts shift the ion beam over the transition which result in an increase of the XUV anode signal
Entry  Wed May 12 09:05:48 2021, Keysight Settings, DAQ,  
 
Entry  Wed May 12 09:04:48 2021, Sebastian, DAQ, Keysight AUtoCal IMG_20210510_143940_resized_20210512_090353546.jpg
 
Entry  Wed May 12 08:42:49 2021, Sebastian, Analysis, Laser scans / coastig beam / no ecooler Screenshot_(156).png
Attached you'll see a first laser scan of ~100GHz in the UV.
Entry  Wed May 12 08:41:36 2021, Sebastian, Analysis, Laser stability 
During night shift the laser was very stable! Only minor fluctuations occured in the UV
Entry  Wed May 12 08:32:04 2021, Sebastian, Analysis, fluorescence & energetic overlap Screenshot_(154).png
During the night shift we saw several rises of the fluorescence (see another entry) and also energetic overlap in coasting beam modus.
Here the laser wavelength was stabilized @ 1028,967nm and electron cooler was switched off because of some fluctuations which we saw in the schottky.
Left part of the schottky picture shows the c3+ beam, the right part is the o4+ contamination.
Entry  Wed May 12 02:34:29 2021, Danyal, General, instabilities in ion frequency fluctuations.jpg
The ion beam moves around, pretty arbitrary. See picture. 
ESR crew believes that it is not due to fluctuations in the HV of the E-Cooler. 
    Reply  Wed May 12 08:10:17 2021, Lars, General, instabilities in ion frequency 
looks like the E-Cooler is responsible for this. If one turns off the electron current, the beam stays stable. 
M.Steck is informed.

> The ion beam moves around, pretty arbitrary. See picture. 
> ESR crew believes that it is not due to fluctuations in the HV of the E-Cooler. 
Entry  Wed May 12 02:16:25 2021, Danyal, Lars, Accelerator, Ion beam position 
Laser Position with scrapers verified. 
1HA: impossible to scratch laser beam, still there at -1.0 mm
2HA: +3mm --> half the laser power on detector; +4.5mm --> gone

2VO: interlock, impossible to move (beam diagnostics is informed and will check)
1VO: +0.2mm --> half laser power, +1.2: laser gone (-1.0mm: also gone)

Ion beam adapted to measured laser beam, Target bump position: -22mm (was -18mm before)
Ion beam position verified with scrapers:
1HA: -1.0mm --> still there
2HA: +4.0mm --> beam gone
Target bump angle: unchanged (+1.2 mrad)
Entry  Tue May 11 20:14:43 2021, Danyal, General, bad ESR vacuum 
I just heard that the ESR vacuum is quite bad. 
There was a small vacuum problem a while ago, it was sealed, but apparently the pressure is not as low as usual.

Markus Steck said that the beam lifetime is only 15 - 20 seconds !!! 

This will seriously complicate some of our test experiments :( 
Entry  Tue May 11 18:29:35 2021, Danyal, General, first ions in the ESR first_ions_are_injected.jpg
 
Entry  Tue May 11 16:33:31 2021, Ken Ueberholz, Detectors, Detector control manual Manual.pdf
Attached to this elog entry is a short manual for the xuv-detector control. If anything is missing or not understandable I can change anything.
Entry  Tue May 11 16:07:59 2021, Sebastian, DAQ, DAQ Manual DAQ_Manual.pdf
Attached you'll find a short manual for operating the whole DAQ system