ID |
Date |
Author |
Category |
Subject |
Text |
|
7
|
Tue May 14 15:07:23 2024 |
Ruijiu, David, Shahab, Xinliang, Zhangmin | Runs | Cooler curve measurement |
Cooler curve measurement
|
7x |
8
|
Tue May 14 19:07:27 2024 |
Shahab | Runs | Broadband measurement / High Sampling rate | Stable beam after a long time:
|
|
9
|
Tue May 14 21:41:11 2024 |
Shahab | Runs | Test Screenshot | |
|
16
|
Wed May 15 00:26:53 2024 |
David, Asahi, Shahab, Chris, Ruijiu | Runs | First data file - 00:26 | Centered resonant frequency on 98Mo+42 at
the 126 harmonic (243.925 MHz) and 211 harmonic
(408.483 MHz).
|
|
26
|
Wed May 15 12:58:12 2024 |
Beatriz, Min, Shahab | Runs | optimizing the mass resolution | Yuri and Sergey still optimizing the mass
resolution.
|
|
29
|
Wed May 15 17:22:43 2024 |
Jeroen, Shahab, Johan | Runs | 98Mo run | Beam tuned at 4:50, data acquisition aligned
for 98Mo at 4:56. |
|
32
|
Wed May 15 18:37:36 2024 |
Jeroen, Johan, Shahab | Runs | Beam returned to ESR | Beam returned at 18:30:55. Taking data with
new triggers. |
|
36
|
Wed May 15 20:40:51 2024 |
Jeroen, Johan | Runs | Beam returned to ESR | 20:39:42 Runs restarted. |
|
39
|
Thu May 16 00:37:41 2024 |
Boguslaw, Camille | Runs | Injection pattern changed | The injection pattern changed on Lassie monitor
(0:27 AM). (picture 1)
|
|
40
|
Thu May 16 04:37:27 2024 |
Boguslaw, Camille | Runs | No beam to ESR | We had no beam in ESR for about 3 minutes |
|
41
|
Thu May 16 07:25:33 2024 |
Mayr, Hannes | Runs | Lassie Screenshot 07:23 | Start of regular screenshots of the Lassie
monitor every 1-2 hours. |
|
42
|
Thu May 16 07:50:39 2024 |
Mayr, Hannes | Runs | Peaks with very high particle rate | Peaks in the particle diagram going to unusual
high 1.4e9 particles. |
|
43
|
Thu May 16 08:58:39 2024 |
Mayr, Hannes | Runs | Fluctuations in particle rate | Particle rates are fluctuating and increasing
from a constant 5e8 to something around 1e9. |
|
44
|
Thu May 16 09:41:56 2024 |
Mayr, Hannes | Runs | No beam | No beam from 09:39 to 10:10 due to a setting
change. The change aims to increase the measurement
time to 10s. |
|
45
|
Thu May 16 10:18:14 2024 |
Mayr, Hannes | Runs | Beam back, DAQ off | Beam is back since 10:10, but DAQ is turned
off to change the setting there.
Measurements starting at 10:18 are only test |
|
46
|
Thu May 16 11:08:27 2024 |
Mayr, Hannes | Runs | DAQ running again | "Real" measurement with good data starting
from 11:07 until approximately 13:00.
Measurement time was changed to 10s with |
|
47
|
Thu May 16 11:13:05 2024 |
Mayr, Hannes | Runs | Rates | With the new timing, the rates now look like
can be seen in the screenshot. |
|
50
|
Thu May 16 13:04:02 2024 |
Mayr, Hannes | Runs | DAQ stopped, change setting to 98Zr | Beam tuning for 98Zr starting at 12:53, following
data should be excluded from analysis. DAQ
was stopped around 13:13. |
|
53
|
Thu May 16 16:10:03 2024 |
Ide, Hubbard | Runs | Lassie Screenshot | Lassie Screenshot taken at 16:09 |
|
54
|
Thu May 16 16:38:11 2024 |
Ide, Hubbard | Runs | No beam to ESR | because of problems in HHT
no beam from 16:36 |
|